IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

466

matching recommendations
Reset
NAICS 3333 Commercial and Service Industry Machinery Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0841 # 16 Y:2011 16 2011 INSTALL AUTOMATIC STACK DAMPER $20,178 $500 Not Implemented
UD0841 # 17 Y:2011 17 2011 INSTALL AUTOMATIC STACK DAMPER $20,941 $600 Implemented
UD0841 # 18 Y:2011 18 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $2,133 $2,098 Implemented
UD0841 # 19 Y:2011 19 2011 REDUCE VENTILATION AIR $174,913 $242,291 Not Implemented
UD0841 # 20 Y:2011 20 2011 USE RADIANT HEATER FOR SPOT HEATING $4,098 $17,940 Not Implemented
UD0841 # 21 Y:2011 21 2011 USE RADIANT HEATER FOR SPOT HEATING $2,147 $4,000 Not Implemented
LL0355 # 01 Y:2011 01 2011 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $121,680 $22,440 Implemented
LL0355 # 02 Y:2011 02 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $7,278 $4,106 Implemented
LL0355 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,642 $1,680 Implemented
LL0355 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,751 $11,200 Implemented
LL0355 # 05 Y:2011 05 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,231 $270 Not Implemented
LL0355 # 06 Y:2011 06 2011 INSTALL OCCUPANCY SENSORS $2,199 $2,220 Not Implemented
LL0355 # 07 Y:2011 07 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $746 $1,155 Not Implemented
LL0355 # 08 Y:2011 08 2011 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $238 $368 Not Implemented
LL0355 # 09 Y:2011 09 2011 INSULATE BARE EQUIPMENT $7 $18 Not Implemented
CO0641 # 01 Y:2010 01 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,720 $410 Not Implemented
CO0641 # 02 Y:2010 02 2010 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,220 $3,400 Not Implemented
CO0641 # 03 Y:2010 03 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,910 $5,160 Not Implemented
CO0641 # 04 Y:2010 04 2010 USE SOLAR HEAT TO MAKE ELECTRICTY $4,170 $31,500 Not Implemented
CO0641 # 05 Y:2010 05 2010 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $3,610 $2,880 Not Implemented
CO0641 # 06 Y:2010 06 2010 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $3,270 $35,500 Not Implemented
CO0641 # 07 Y:2010 07 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,300 $5,160 Not Implemented
CO0641 # 08 Y:2010 08 2010 INSTALL OCCUPANCY SENSORS $520 $810 Not Implemented
CO0641 # 09 Y:2010 09 2010 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $320 $650 Not Implemented
MA0661 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $562 $588 Implemented