IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

548

matching recommendations
Reset
NAICS 33361 Engine, Turbine, and Power Transmission Equipment Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0387 # 02 Y:2006 02 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $24,561 $2,190 Implemented
UF0387 # 03 Y:2006 03 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $7,957 $0 Not Implemented
UF0387 # 04 Y:2006 04 2006 AIR CONDITION ONLY SPACE NECESSARY $2,639 $3,360 Not Implemented
UF0387 # 05 Y:2006 05 2006 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $4,265 $578 Not Implemented
UF0387 # 06 Y:2006 06 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,577 $370 Implemented
UF0387 # 07 Y:2006 07 2006 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $21,479 $0 Implemented
UF0387 # 08 Y:2006 08 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,017 $0 Implemented
UF0387 # 09 Y:2006 09 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,106 $6,458 Implemented
UF0387 # 10 Y:2006 10 2006 INSTALL OCCUPANCY SENSORS $209 $140 Not Implemented
WI0510 # 01 Y:2006 01 2006 INSTALL TIMERS AND/OR THERMOSTATS $12,014 $0 Implemented
WI0510 # 02 Y:2006 02 2006 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,865 $2,000 Not Implemented
WI0510 # 03 Y:2006 03 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,944 $23,000 Implemented
WI0510 # 04 Y:2006 04 2006 RECOVER WASTE HEAT FROM EQUIPMENT $4,554 $1,000 Not Implemented
WI0510 # 05 Y:2006 05 2006 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $32,657 $3,352 Not Implemented
WI0510 # 06 Y:2006 06 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,135 $640 Implemented
WI0510 # 07 Y:2006 07 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $443 $438 Not Implemented
WI0510 # 08 Y:2006 08 2006 INSTALL SET-BACK TIMERS $340 $100 Implemented
WV0329 # 01 Y:2005 01 2005 USE RADIANT HEATER FOR SPOT HEATING $35,587 $11,800 Implemented
WV0329 # 02 Y:2005 02 2005 COVER OPEN TANKS $19,992 $60,000 Not Implemented
WV0329 # 03 Y:2005 03 2005 RECOVER WASTE HEAT FROM EQUIPMENT $16,985 $1,088 Not Implemented
WV0329 # 04 Y:2005 04 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $12,841 $10,360 Implemented
WV0329 # 05 Y:2005 05 2005 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $9,423 $8,360 Implemented
WV0329 # 06 Y:2005 06 2005 DEVELOP A REPAIR/REPLACE POLICY $6,007 $729 Implemented
WV0329 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,535 $8,398 Implemented
WV0329 # 08 Y:2005 08 2005 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $4,468 $11,504 Implemented