Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
404
matching recommendationsNAICS | 33391 | Pump and Compressor Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0512 # 07 Y:2006 | 07 | 2006 | REUSE RAGS UNTIL COMPLETELY SOILED | $1,300 | $0 | Not Implemented |
AM0512 # 08 Y:2006 | 08 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $800 | $0 | Not Implemented |
AM0512 # 09 Y:2006 | 09 | 2006 | USE SYNTHETIC LUBRICANT | $700 | $0 | Not Implemented |
AM0512 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $230 | $0 | Not Implemented |
IA0372 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $496 | $619 | Implemented |
IA0372 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $381 | $510 | Implemented |
IA0372 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,734 | $5,978 | Implemented |
IA0372 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $519 | $462 | Implemented |
IA0372 # 05 Y:2005 | 05 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $45,000 | $75,000 | Implemented |
IA0372 # 06 Y:2005 | 06 | 2005 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,091 | $3,517 | Not Implemented |
TA0092 # 01 Y:2005 | 01 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,280 | $2,300 | Not Implemented |
TA0092 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,280 | $1,300 | Implemented |
TA0092 # 03 Y:2005 | 03 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $3,580 | $5 | Implemented |
TA0092 # 04 Y:2005 | 04 | 2005 | REDUCE OR ELIMINATE WASTE | $2,710 | $36 | Implemented |
TA0092 # 05 Y:2005 | 05 | 2005 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $2,200 | $111 | Not Implemented |
TA0092 # 06 Y:2005 | 06 | 2005 | SHUT OFF AIR CONDITIONING IN WINTER HEATING SEASON | $1,140 | $0 | Implemented |
TA0092 # 07 Y:2005 | 07 | 2005 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $535 | $155 | Not Implemented |
TA0092 # 08 Y:2005 | 08 | 2005 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $250 | $0 | Not Implemented |
TA0086 # 01 Y:2004 | 01 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,742 | $0 | Not Implemented |
TA0086 # 02 Y:2004 | 02 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,520 | $5,800 | Not Implemented |
TA0086 # 03 Y:2004 | 03 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,950 | $5,000 | Not Implemented |
TA0086 # 04 Y:2004 | 04 | 2004 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,350 | $0 | Not Implemented |
TA0086 # 05 Y:2004 | 05 | 2004 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,605 | $2,000 | Not Implemented |
CO0553 # 01 Y:2004 | 01 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $5,190 | $20,000 | Not Implemented |
CO0553 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,980 | $180 | Implemented |