Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,963
matching recommendationsNAICS | 334 | Computer and Electronic Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0263 # 08 Y:2008 | 08 | 2008 | INSTALL OCCUPANCY SENSORS | $307 | $474 | Implemented |
SU0263 # 09 Y:2008 | 09 | 2008 | REDUCE VENTILATION AIR | $1,611 | $13,919 | Not Implemented |
CO0610 # 01 Y:2008 | 01 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,340 | $13,163 | Implemented |
CO0610 # 02 Y:2008 | 02 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,470 | $1,400 | Implemented |
CO0610 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $880 | $500 | Implemented |
CO0610 # 04 Y:2008 | 04 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,690 | $15,668 | Implemented |
CO0610 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,680 | $3,991 | Implemented |
CO0610 # 06 Y:2008 | 06 | 2008 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,610 | $11,000 | Not Implemented |
CO0610 # 07 Y:2008 | 07 | 2008 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $530 | $500 | Implemented |
MA0627 # 01 Y:2008 | 01 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $52,302 | $35,000 | Implemented |
MA0627 # 02 Y:2008 | 02 | 2008 | REDUCE VENTILATION AIR | $8,813 | $16,000 | Implemented |
MA0627 # 03 Y:2008 | 03 | 2008 | OPTIMIZE PLANT POWER FACTOR | $6,984 | $8,550 | Implemented |
MA0627 # 04 Y:2008 | 04 | 2008 | USE MINIMUM SAFE OVEN VENTILATION | $6,674 | $5,000 | Not Implemented |
MA0627 # 05 Y:2008 | 05 | 2008 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,648 | $4,300 | Not Implemented |
MA0627 # 06 Y:2008 | 06 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $948 | $1,000 | Implemented |
IA0417 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36,598 | $46,276 | Not Implemented |
IA0417 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,956 | $13,071 | Not Implemented |
IA0417 # 03 Y:2007 | 03 | 2007 | INSTALL OCCUPANCY SENSORS | $1,650 | $1,078 | Not Implemented |
IA0417 # 04 Y:2007 | 04 | 2007 | ADD AREA LIGHTING SWITCHES | $7,664 | $1,875 | Not Implemented |
IA0417 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,033 | $3,978 | Not Implemented |
IA0417 # 06 Y:2007 | 06 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,044 | $2,000 | Not Implemented |
LL0285 # 01 Y:2007 | 01 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,109 | $60 | Implemented |
LL0285 # 02 Y:2007 | 02 | 2007 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $1,914 | $1,160 | Implemented |
LL0285 # 03 Y:2007 | 03 | 2007 | INSTALL OCCUPANCY SENSORS | $1,056 | $900 | Not Implemented |
LL0285 # 04 Y:2007 | 04 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $603 | $252 | Implemented |