Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
42
matching recommendationsNAICS | 33431 | Audio and Video Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0947 # 17 Y:2016 | 17 | 2016 | DISCONNECT BALLASTS | $694 | $345 | Not Implemented |
UD0947 # 12 Y:2016 | 12 | 2016 | USE RADIANT HEATER FOR SPOT HEATING | $8,339 | $23,265 | Not Implemented |
UD0947 # 13 Y:2016 | 13 | 2016 | OPTIMIZE PLANT POWER FACTOR | $994 | $2,000 | Not Implemented |
UD0947 # 14 Y:2016 | 14 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,211 | $81,318 | Not Implemented |
UD0947 # 15 Y:2016 | 15 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,498 | $20,246 | Not Implemented |
UD0947 # 16 Y:2016 | 16 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,398 | $51,121 | Not Implemented |
UD0947 # 06 Y:2016 | 06 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $893 | $680 | Not Implemented |
UD0947 # 05 Y:2016 | 05 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $462 | $1,000 | Not Implemented |
UD0947 # 04 Y:2016 | 04 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $618 | $200 | Not Implemented |
UD0947 # 03 Y:2016 | 03 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $953 | $2,000 | Not Implemented |
UD0947 # 02 Y:2016 | 02 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $6,835 | $0 | Implemented |
UD0947 # 01 Y:2016 | 01 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $10,920 | $1,000 | Implemented |
CO0643 # 05 Y:2010 | 05 | 2010 | REDUCE VENTILATION AIR | $270 | $1,290 | Not Implemented |
CO0643 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,370 | $33,822 | Implemented |
CO0643 # 03 Y:2010 | 03 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,270 | $1,680 | Not Implemented |
CO0643 # 02 Y:2010 | 02 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $4,470 | $27,000 | Not Implemented |
CO0643 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,130 | $340 | Implemented |