IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

24

matching recommendations
Reset
NAICS 334416 Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MZ0057 # 10 Y:2010 10 2010 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,259 $0 Implemented
MZ0057 # 21 Y:2010 21 2010 INSULATE BARE EQUIPMENT $248 $300 Implemented
MZ0057 # 20 Y:2010 20 2010 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $14,800 $48,840 Not Implemented
MZ0057 # 19 Y:2010 19 2010 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $19,660 $18,000 Implemented
MZ0057 # 18 Y:2010 18 2010 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $12,000 $0 Implemented
MZ0057 # 17 Y:2010 17 2010 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $652 $0 Not Implemented
MZ0057 # 16 Y:2010 16 2010 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $52 $50 Implemented
MZ0057 # 15 Y:2010 15 2010 USE OPTIMUM THICKNESS INSULATION $11,828 $5,000 Not Implemented
MZ0057 # 14 Y:2010 14 2010 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $3,194 $2,000 Implemented
MZ0057 # 13 Y:2010 13 2010 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,940 $0 Implemented
MZ0057 # 12 Y:2010 12 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $3,016 $0 Implemented
MZ0057 # 11 Y:2010 11 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,919 $1,300 Implemented
MZ0057 # 09 Y:2010 09 2010 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $2,104 $100 Implemented
MZ0057 # 08 Y:2010 08 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $186 $300 Implemented
MZ0057 # 07 Y:2010 07 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,315 $9,660 Implemented
MZ0057 # 06 Y:2010 06 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,198 $10,240 Implemented
MZ0057 # 05 Y:2010 05 2010 INSTALL OCCUPANCY SENSORS $1,212 $2,410 Implemented
MZ0057 # 04 Y:2010 04 2010 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $1,597 $250 Implemented
MZ0057 # 03 Y:2010 03 2010 KEEP EQUIPMENT CLEAN $5,750 $0 Implemented
MZ0057 # 02 Y:2010 02 2010 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $145,366 $500,000 Not Implemented
MZ0057 # 01 Y:2010 01 2010 SHADE WINDOWS FROM SUMMER SUN $259,173 $46,607 Implemented
MZ0041 # 01 Y:2009 01 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $45,616 $42,000 Implemented
MZ0041 # 03 Y:2009 03 2009 INSTALL OCCUPANCY SENSORS $1,693 $1,780 Implemented
MZ0041 # 02 Y:2009 02 2009 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $60,170 $43,800 Implemented