Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20
matching recommendationsNAICS | 334510 | Electromedical and Electrotherapeutic Apparatus Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0290 # 05 Y:2016 | 05 | 2016 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $5,243 | $6,421 | Not Implemented |
MI0290 # 14 Y:2016 | 14 | 2016 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $396 | $317 | Implemented |
MI0290 # 13 Y:2016 | 13 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,396 | $3,240 | Not Implemented |
MI0290 # 12 Y:2016 | 12 | 2016 | REDUCE HEAT GAIN BY WINDOW TINTING | $1,443 | $2,240 | Not Implemented |
MI0290 # 11 Y:2016 | 11 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,703 | $1,080 | Implemented |
MI0290 # 10 Y:2016 | 10 | 2016 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,792 | $280 | Implemented |
MI0290 # 09 Y:2016 | 09 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,622 | $40 | Implemented |
MI0290 # 08 Y:2016 | 08 | 2016 | INSTALL OCCUPANCY SENSORS | $3,248 | $2,165 | Implemented |
MI0290 # 07 Y:2016 | 07 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,847 | $6,880 | Not Implemented |
MI0290 # 06 Y:2016 | 06 | 2016 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $5,225 | $15,465 | Not Implemented |
MI0290 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,730 | $16,200 | Implemented |
MI0290 # 03 Y:2016 | 03 | 2016 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $22,761 | $41,950 | Not Implemented |
MI0290 # 02 Y:2016 | 02 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $50,831 | $40 | Implemented |
MI0290 # 01 Y:2016 | 01 | 2016 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $81,253 | $1,120 | Implemented |
MI0186 # 01 Y:2009 | 01 | 2009 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $160,282 | $0 | Implemented |
MI0186 # 06 Y:2009 | 06 | 2009 | DISCONNECT BALLASTS | $3,090 | $900 | Not Implemented |
MI0186 # 05 Y:2009 | 05 | 2009 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $24,293 | $1,600 | Not Implemented |
MI0186 # 04 Y:2009 | 04 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $56,948 | $10,000 | Implemented |
MI0186 # 03 Y:2009 | 03 | 2009 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $76,266 | $28,000 | Not Implemented |
MI0186 # 02 Y:2009 | 02 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $110,625 | $4,000 | Implemented |