Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,095

matching recommendations
Reset
NAICS 335 Electrical Equipment, Appliance, and Component Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0821 # 04 Y:2021 04 2021 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,780 $4,216 Not Implemented
AM0821 # 05 Y:2021 05 2021 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,057 $12 Not Implemented
AM0821 # 06 Y:2021 06 2021 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $425 $52 Not Implemented
SD0606 # 01 Y:2021 01 2021 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $52,049 $46,262 Not Implemented
SD0606 # 02 Y:2021 02 2021 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,424 $3,341 Not Implemented
SD0606 # 03 Y:2021 03 2021 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,375 $300 Implemented
SD0606 # 04 Y:2021 04 2021 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,222 $4,345 Not Implemented
SD0606 # 05 Y:2021 05 2021 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $539 $0 Implemented
UD1026 # 01 Y:2021 01 2021 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,601 $0 Implemented
UD1026 # 02 Y:2021 02 2021 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $174,302 $45,000 Implemented
UD1026 # 03 Y:2021 03 2021 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $58,812 $45,000 Not Implemented
UD1026 # 04 Y:2021 04 2021 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $441,982 $200,000 Not Implemented
UD1026 # 05 Y:2021 05 2021 UTILIZE A LESS EXPENSIVE COOLING METHOD $42,343 $88,894 Implemented
UD1026 # 06 Y:2021 06 2021 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $817 $0 Not Implemented
DL0186 # 01 Y:2021 01 2021 TURN OFF EQUIPMENT WHEN NOT IN USE $5,690 $0 Implemented
DL0186 # 02 Y:2021 02 2021 TURN OFF EQUIPMENT WHEN NOT IN USE $2,738 $0 Implemented
DL0186 # 03 Y:2021 03 2021 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,598 $6,500 Not Implemented
DL0186 # 04 Y:2021 04 2021 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $773 $799 Implemented
DL0186 # 05 Y:2021 05 2021 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $875 $3,275 Implemented
DL0186 # 06 Y:2021 06 2021 ELIMINATE LEAKS IN WATER LINES AND VALVES $2,060 $1,500 Implemented
DL0186 # 07 Y:2021 07 2021 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $182 $0 Implemented
DL0186 # 08 Y:2021 08 2021 REPAIR AND ELIMINATE STEAM LEAKS $2,190 $3,000 Implemented
DL0186 # 09 Y:2021 09 2021 REPLACE BOILER $2,104 $7,098 Not Implemented
DL0186 # 10 Y:2021 10 2021 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,852 $0 Implemented
DL0186 # 11 Y:2021 11 2021 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $115 $0 Not Implemented