Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,095
matching recommendationsNAICS | 335 | Electrical Equipment, Appliance, and Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0045 # 01 Y:2014 | 01 | 2014 | RECYCLE WHITE WATER | $6,827 | $13,958 | Not Implemented |
WM0045 # 02 Y:2014 | 02 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,114 | $2,500 | Not Implemented |
WM0045 # 03 Y:2014 | 03 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $2,701 | $0 | Implemented |
WM0045 # 04 Y:2014 | 04 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,111 | $2,030 | Not Implemented |
WM0045 # 05 Y:2014 | 05 | 2014 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,440 | $940 | Not Implemented |
WM0045 # 06 Y:2014 | 06 | 2014 | IMPROVE SPACE COMFORT CONDITIONING | $4,160 | $350 | Not Implemented |
WM0045 # 07 Y:2014 | 07 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $478 | $280 | Implemented |
WM0045 # 08 Y:2014 | 08 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $313 | $630 | Not Implemented |
WM0045 # 09 Y:2014 | 09 | 2014 | COVER OPEN TANKS | $51 | $0 | Implemented |
WM0045 # 10 Y:2014 | 10 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $38 | $100 | Not Implemented |
WM0045 # 11 Y:2014 | 11 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,255 | $1,220 | Implemented |
TT0131 # 01 Y:2014 | 01 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,347 | $972 | Not Implemented |
TT0131 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,605 | $30,150 | Not Implemented |
TT0131 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,715 | $63,236 | Implemented |
TT0131 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,202 | $16,590 | Implemented |
TT0131 # 05 Y:2014 | 05 | 2014 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $3,687 | $8,925 | Not Implemented |
TT0131 # 06 Y:2014 | 06 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $206,605 | $247,740 | Not Implemented |
SU0362 # 01 Y:2014 | 01 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,295 | $202 | Implemented |
SU0362 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $2,464 | $1,840 | Implemented |
SU0362 # 03 Y:2014 | 03 | 2014 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,404 | $2,959 | Implemented |
SU0362 # 04 Y:2014 | 04 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,593 | $15,784 | Not Implemented |
SU0362 # 05 Y:2014 | 05 | 2014 | ELIMINATE/REDUCE AN OPERATION | $4,540 | $15,840 | Not Implemented |
SU0362 # 06 Y:2014 | 06 | 2014 | UPGRADE OBSOLETE EQUIPMENT | $289 | $1,250 | Implemented |
SU0361 # 01 Y:2014 | 01 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,135 | $0 | Implemented |
SU0361 # 02 Y:2014 | 02 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $376 | $0 | Not Implemented |