Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,095
matching recommendationsNAICS | 335 | Electrical Equipment, Appliance, and Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0449 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,300 | $10,168 | Implemented |
NC0449 # 04 Y:2012 | 04 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,288 | $37,820 | Not Implemented |
NC0449 # 05 Y:2012 | 05 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,027 | $6,500 | Not Implemented |
NC0449 # 06 Y:2012 | 06 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,521 | $3,200 | Not Implemented |
OK0826 # 01 Y:2012 | 01 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,497 | $27,016 | Not Implemented |
OK0826 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $50,910 | $106,879 | Not Implemented |
OK0826 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,061 | $38,900 | Not Implemented |
OK0826 # 04 Y:2012 | 04 | 2012 | COVER OPEN TANKS | $1,576 | $0 | Not Implemented |
OK0826 # 05 Y:2012 | 05 | 2012 | REDUCE EXCESSIVE BOILER BLOWDOWN | $13,280 | $31,040 | Not Implemented |
OK0826 # 06 Y:2012 | 06 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,630 | $4,000 | Not Implemented |
OK0826 # 07 Y:2012 | 07 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $20,532 | $9,400 | Not Implemented |
BD0410 # 01 Y:2012 | 01 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,500 | $5,500 | Not Implemented |
BD0410 # 02 Y:2012 | 02 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,850 | $20 | Not Implemented |
BD0410 # 03 Y:2012 | 03 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $821 | $10,000 | Not Implemented |
BD0410 # 04 Y:2012 | 04 | 2012 | USE PHOTOCELL CONTROLS | $4,755 | $4,050 | Not Implemented |
BD0410 # 05 Y:2012 | 05 | 2012 | USE SYNTHETIC LUBRICANT | $3,095 | $1,000 | Not Implemented |
BD0410 # 06 Y:2012 | 06 | 2012 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,832 | $4,900 | Not Implemented |
BD0410 # 07 Y:2012 | 07 | 2012 | INSTALL OCCUPANCY SENSORS | $2,094 | $2,025 | Not Implemented |
BD0410 # 08 Y:2012 | 08 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,907 | $500 | Not Implemented |
BD0410 # 09 Y:2012 | 09 | 2012 | INSTALL AUTOMATIC STACK DAMPER | $1,223 | $1,750 | Not Implemented |
MI0215 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,517 | $8,000 | Implemented |
MI0215 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,090 | $1,320 | Not Implemented |
MI0215 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,007 | $21,070 | Not Implemented |
MI0215 # 04 Y:2012 | 04 | 2012 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $6,640 | $12,200 | Not Implemented |
MI0215 # 05 Y:2012 | 05 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,815 | $1,300 | Implemented |