Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
59
matching recommendationsNAICS | 335121 | Residential Electric Lighting Fixture Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0409 # 01 Y:2016 | 01 | 2016 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $802 | $0 | Not Implemented |
SU0409 # 07 Y:2016 | 07 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $498 | $1,262 | Implemented |
SU0409 # 06 Y:2016 | 06 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $36 | $63 | Implemented |
SU0409 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $211 | $160 | Not Implemented |
SU0409 # 03 Y:2016 | 03 | 2016 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $1,899 | $1,546 | Implemented |
SU0409 # 02 Y:2016 | 02 | 2016 | REDUCE VENTILATION AIR | $1,604 | $822 | Implemented |
SU0409 # 04 Y:2016 | 04 | 2016 | INSTALL / REPAIR INSULATION ON STEAM LINES | $292 | $233 | Implemented |
WV0425 # 05 Y:2011 | 05 | 2011 | ADD AREA LIGHTING SWITCHES | $5,883 | $20,000 | Not Implemented |
WV0425 # 06 Y:2011 | 06 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,760 | $0 | Implemented |
WV0425 # 04 Y:2011 | 04 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $9,251 | $9,400 | Implemented |
WV0425 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $29,992 | $32,300 | Not Implemented |
WV0425 # 02 Y:2011 | 02 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $128,784 | $122,980 | Not Implemented |
WV0425 # 01 Y:2011 | 01 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $358,430 | $44,500 | Not Implemented |
WV0425 # 07 Y:2011 | 07 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,578 | $3,004 | Implemented |
WV0425 # 08 Y:2011 | 08 | 2011 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,189 | $4,200 | Not Implemented |
WV0345 # 13 Y:2006 | 13 | 2006 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,389 | $6,500 | Not Implemented |
WV0345 # 12 Y:2006 | 12 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $5,468 | $800 | Implemented |
WV0345 # 11 Y:2006 | 11 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,570 | $0 | Not Implemented |
WV0345 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,809 | $49,405 | Implemented |
WV0345 # 08 Y:2006 | 08 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,402 | $1,000 | Implemented |
WV0345 # 07 Y:2006 | 07 | 2006 | REDUCE VENTILATION AIR | $10,829 | $6,280 | Not Implemented |
WV0345 # 06 Y:2006 | 06 | 2006 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $14,670 | $1,000 | Implemented |
WV0345 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,346 | $2,805 | Implemented |
WV0345 # 04 Y:2006 | 04 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $22,653 | $26,300 | Not Implemented |
WV0345 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,574 | $60,657 | Implemented |