Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
301
matching recommendationsNAICS | 33593 | Wiring Device Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0694 # 03 Y:2012 | 03 | 2012 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $5,619 | $0 | Implemented |
MA0694 # 04 Y:2012 | 04 | 2012 | INSULATE BARE EQUIPMENT | $3,042 | $665 | Not Implemented |
MA0694 # 05 Y:2012 | 05 | 2012 | INSULATE BARE EQUIPMENT | $2,300 | $16,608 | Implemented |
MA0694 # 06 Y:2012 | 06 | 2012 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $1,515 | $3,410 | Not Implemented |
MA0694 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $503 | $900 | Implemented |
MA0694 # 08 Y:2012 | 08 | 2012 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $253 | $900 | Not Implemented |
MI0215 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,517 | $8,000 | Implemented |
MI0215 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,090 | $1,320 | Not Implemented |
MI0215 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,007 | $21,070 | Not Implemented |
MI0215 # 04 Y:2012 | 04 | 2012 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $6,640 | $12,200 | Not Implemented |
MI0215 # 05 Y:2012 | 05 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,815 | $1,300 | Implemented |
MI0215 # 06 Y:2012 | 06 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,514 | $50 | Not Implemented |
MI0215 # 07 Y:2012 | 07 | 2012 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $625 | $4,571 | Not Implemented |
NC0435 # 01 Y:2011 | 01 | 2011 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $23,638 | $0 | Not Implemented |
NC0435 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $44,479 | $72,211 | Implemented |
NC0435 # 03 Y:2011 | 03 | 2011 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,887 | $7,760 | Implemented |
NC0435 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $661 | $1,911 | Implemented |
NC0435 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $124 | $31 | Not Implemented |
NC0435 # 06 Y:2011 | 06 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $295 | $1,500 | Implemented |
NC0430 # 01 Y:2011 | 01 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,839 | $0 | Implemented |
NC0430 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,052 | $100 | Implemented |
NC0430 # 03 Y:2011 | 03 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,314 | $150 | Implemented |
NC0430 # 04 Y:2011 | 04 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $11,250 | $22,950 | Not Implemented |
NC0430 # 05 Y:2011 | 05 | 2011 | REPLACE BOILER | $3,539 | $11,800 | Not Implemented |
NC0430 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,385 | $4,833 | Implemented |