IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

17

matching recommendations
Reset
NAICS 336212 Truck Trailer Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA0074 # 02 Y:2012 02 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,736 $2,500 Implemented
UA0074 # 03 Y:2012 03 2012 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,094 $1,680 Not Implemented
UA0074 # 04 Y:2012 04 2012 RECOVER WASTE HEAT FROM EQUIPMENT $1,815 $539 Not Implemented
UA0074 # 05 Y:2012 05 2012 USE RADIANT HEATER FOR SPOT HEATING $4,712 $4,728 Not Implemented
UA0074 # 06 Y:2012 06 2012 INSTALL TIMERS AND/OR THERMOSTATS $5,313 $2,040 Not Implemented
UA0074 # 07 Y:2012 07 2012 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,847 $2 Implemented
UA0074 # 01 Y:2012 01 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,718 $480 Implemented
UA3005 # 10 Y:2010 10 2010 INSTALL TIMERS AND/OR THERMOSTATS $2,972 $510 Not Implemented
UA3005 # 09 Y:2010 09 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $6,056 $2,750 Not Implemented
UA3005 # 08 Y:2010 08 2010 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $122,417 $2,400 Implemented
UA3005 # 07 Y:2010 07 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,333 $1,000 Not Implemented
UA3005 # 06 Y:2010 06 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,840 $400 Not Implemented
UA3005 # 05 Y:2010 05 2010 RECOVER WASTE HEAT FROM EQUIPMENT $9,061 $5,448 Not Implemented
UA3005 # 04 Y:2010 04 2010 UPGRADE CONTROLS ON COMPRESSORS $9,502 $20,000 Implemented
UA3005 # 03 Y:2010 03 2010 INSTALL OCCUPANCY SENSORS $2,974 $730 Not Implemented
UA3005 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $27,085 $42,861 Implemented
UA3005 # 01 Y:2010 01 2010 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $30,246 $34,285 Not Implemented