IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

262

matching recommendations
Reset
NAICS 3363 Motor Vehicle Parts Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA3014 # 02 Y:2011 02 2011 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $71,901 $30,750 Not Implemented
UA3014 # 03 Y:2011 03 2011 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $72,048 $98,000 Not Implemented
UA3014 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,700 $60,860 Not Implemented
UA3014 # 05 Y:2011 05 2011 INSTALL OCCUPANCY SENSORS $20,767 $13,730 Implemented
UA3014 # 06 Y:2011 06 2011 DISCONNECT BALLASTS $5,801 $405 Implemented
UA3014 # 07 Y:2011 07 2011 OPTIMIZE PLANT POWER FACTOR $29,663 $26,400 Not Implemented
UA3014 # 08 Y:2011 08 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $92,285 $51,748 Not Implemented
UA3014 # 09 Y:2011 09 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $269,372 $630,225 Not Implemented
UA3013 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $44,925 $31,378 Not Implemented
UA3013 # 02 Y:2011 02 2011 USE PHOTOCELL CONTROLS $1,196 $225 Not Implemented
UA3013 # 03 Y:2011 03 2011 INSTALL OCCUPANCY SENSORS $4,650 $7,410 Not Implemented
UA3013 # 04 Y:2011 04 2011 REDUCE FLUID FLOW RATES $6,480 $2,168 Not Implemented
UA3002 # 01 Y:2010 01 2010 RECOVER WASTE HEAT FROM EQUIPMENT $2,042 $4,063 Not Implemented
UA3002 # 02 Y:2010 02 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,184 $640 Not Implemented
UA3002 # 03 Y:2010 03 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $258 $600 Not Implemented
UA3002 # 04 Y:2010 04 2010 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $10,623 $0 Not Implemented
UA3002 # 05 Y:2010 05 2010 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $10,185 $0 Not Implemented
UA3001 # 01 Y:2010 01 2010 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $42,535 $960 Implemented
UA3001 # 02 Y:2010 02 2010 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $22,945 $37,030 Not Implemented
UA3001 # 03 Y:2010 03 2010 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $6,600 $10,620 Not Implemented
UA3001 # 04 Y:2010 04 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,740 $7,420 Implemented
UA3001 # 05 Y:2010 05 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,382 $640 Implemented
UA3001 # 06 Y:2010 06 2010 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,833 $10,000 Not Implemented
UA3001 # 07 Y:2010 07 2010 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $12,114 $0 Implemented
UA3001 # 08 Y:2010 08 2010 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $970 $2,880 Implemented