Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17
matching recommendationsNAICS | 33635 | Motor Vehicle Transmission and Power Train Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0769 # 09 Y:2007 | 09 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $13,400 | $600 | Not Implemented |
UD0769 # 17 Y:2007 | 17 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,242 | $0 | Implemented |
UD0769 # 16 Y:2007 | 16 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,447 | $520 | Implemented |
UD0769 # 15 Y:2007 | 15 | 2007 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,800 | $500 | Implemented |
UD0769 # 14 Y:2007 | 14 | 2007 | REDUCE VENTILATION AIR | $2,208 | $590 | Implemented |
UD0769 # 13 Y:2007 | 13 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $3,980 | $0 | Implemented |
UD0769 # 12 Y:2007 | 12 | 2007 | REDUCE VENTILATION AIR | $17,703 | $26,910 | Not Implemented |
UD0769 # 11 Y:2007 | 11 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,569 | $3,275 | Implemented |
UD0769 # 10 Y:2007 | 10 | 2007 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $10,000 | $25,000 | Not Implemented |
UD0769 # 01 Y:2007 | 01 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $126,798 | $0 | Implemented |
UD0769 # 08 Y:2007 | 08 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $23,200 | $400 | Implemented |
UD0769 # 07 Y:2007 | 07 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $25,268 | $0 | Implemented |
UD0769 # 06 Y:2007 | 06 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $39,200 | $130,000 | Implemented |
UD0769 # 05 Y:2007 | 05 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $44,667 | $28,125 | Implemented |
UD0769 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $61,170 | $110,000 | Implemented |
UD0769 # 03 Y:2007 | 03 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $63,509 | $110,000 | Implemented |
UD0769 # 02 Y:2007 | 02 | 2007 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $119,000 | $0 | Implemented |