IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

21

matching recommendations
Reset
NAICS 336350 Motor Vehicle Transmission and Power Train Parts Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0339 # 02 Y:2013 02 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $10,664 $994 Not Implemented
SU0339 # 12 Y:2013 12 2013 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $381 $1,312 Not Implemented
SU0339 # 11 Y:2013 11 2013 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,108 $20,639 Not Implemented
SU0339 # 10 Y:2013 10 2013 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $716 $1,567 Not Implemented
SU0339 # 09 Y:2013 09 2013 ELIMINATE/REDUCE AN OPERATION $13,535 $19,680 Implemented
SU0339 # 08 Y:2013 08 2013 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $35,885 $54,000 Not Implemented
SU0339 # 07 Y:2013 07 2013 INSTALL OCCUPANCY SENSORS $2,294 $2,093 Implemented
SU0339 # 06 Y:2013 06 2013 REDUCE VENTILATION AIR $1,471 $882 Not Implemented
SU0339 # 05 Y:2013 05 2013 ADD AREA LIGHTING SWITCHES $429 $152 Implemented
SU0339 # 04 Y:2013 04 2013 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $18,079 $3,600 Implemented
SU0339 # 03 Y:2013 03 2013 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $1,064 $125 Implemented
SU0339 # 01 Y:2013 01 2013 INSTALL SPECTRAL REFLECTORS / DELAMP $4,610 $0 Implemented
SU0319 # 01 Y:2012 01 2012 USE SYNTHETIC LUBRICANT $167 $0 Not Implemented
SU0319 # 09 Y:2012 09 2012 OPTIMIZE PLANT POWER FACTOR $21,253 $79,288 Not Implemented
SU0319 # 08 Y:2012 08 2012 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $503 $1,805 Not Implemented
SU0319 # 07 Y:2012 07 2012 RECOVER WASTE HEAT FROM EQUIPMENT $250,480 $603,880 Implemented
SU0319 # 06 Y:2012 06 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,147 $1,075 Implemented
SU0319 # 05 Y:2012 05 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,410 $2,500 Implemented
SU0319 # 04 Y:2012 04 2012 ELIMINATE/REDUCE AN OPERATION $24,117 $15,840 Implemented
SU0319 # 03 Y:2012 03 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $13,648 $1,000 Not Implemented
SU0319 # 02 Y:2012 02 2012 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $17 $0 Not Implemented