IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

507

matching recommendations
Reset
NAICS 336370 Motor Vehicle Metal Stamping
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0386 # 03 Y:2012 03 2012 RECOVER WASTE HEAT FROM EQUIPMENT $6,854 $7,104 Not Implemented
MS0386 # 04 Y:2012 04 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,951 $386 Implemented
MS0386 # 05 Y:2012 05 2012 INSTALL OCCUPANCY SENSORS $857 $97 Not Implemented
UA0060 # 01 Y:2011 01 2011 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $10,956 $34,000 Not Implemented
UA0060 # 02 Y:2011 02 2011 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $804 $2,040 Not Implemented
UA0060 # 03 Y:2011 03 2011 AIR CONDITION ONLY SPACE NECESSARY $20,888 $14,995 Not Implemented
UA3013 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $44,925 $31,378 Not Implemented
UA3013 # 02 Y:2011 02 2011 USE PHOTOCELL CONTROLS $1,196 $225 Not Implemented
UA3013 # 03 Y:2011 03 2011 INSTALL OCCUPANCY SENSORS $4,650 $7,410 Not Implemented
UA3013 # 04 Y:2011 04 2011 REDUCE FLUID FLOW RATES $6,480 $2,168 Not Implemented
WV0415 # 01 Y:2010 01 2010 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $86,422 $15,000 Not Implemented
WV0415 # 02 Y:2010 02 2010 UPGRADE CONTROLS ON COMPRESSORS $21,876 $30,800 Not Implemented
WV0415 # 03 Y:2010 03 2010 REDUCE VENTILATION AIR $18,153 $5,000 Not Implemented
WV0415 # 04 Y:2010 04 2010 USE DEMAND CONTROLLER OR LOAD SHEDDER $14,296 $7,820 Implemented
WV0415 # 05 Y:2010 05 2010 USE RADIANT HEATER FOR SPOT HEATING $12,353 $34,050 Not Implemented
WV0415 # 06 Y:2010 06 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,767 $1,503 Implemented
WV0415 # 07 Y:2010 07 2010 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,621 $2,000 Implemented
WV0415 # 08 Y:2010 08 2010 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $5,733 $700 Implemented
WV0415 # 09 Y:2010 09 2010 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $4,603 $5,265 Not Implemented
WV0415 # 10 Y:2010 10 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,852 $884 Implemented
WV0415 # 11 Y:2010 11 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,398 $4,490 Implemented
WV0415 # 12 Y:2010 12 2010 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,032 $1,312 Implemented
WV0408 # 01 Y:2010 01 2010 USE RADIANT HEATER FOR SPOT HEATING $47,191 $33,500 Not Implemented
WV0408 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $44,874 $82 Implemented
WV0408 # 03 Y:2010 03 2010 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $23,707 $85,000 Not Implemented