Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
237
matching recommendationsNAICS | 336411 | Aircraft Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0846 # 01 Y:2013 | 01 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,801 | $9,541 | Not Implemented |
OK0846 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,561 | $525 | Implemented |
OK0846 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $1,618 | $31,000 | Not Implemented |
OK0846 # 04 Y:2013 | 04 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $7,018 | $8,775 | Not Implemented |
OK0846 # 05 Y:2013 | 05 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,467 | $13,650 | Implemented |
OK0846 # 06 Y:2013 | 06 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,061 | $3,840 | Implemented |
OK0846 # 07 Y:2013 | 07 | 2013 | OPTIMIZE PLANT POWER FACTOR | $32,267 | $17,174 | Implemented |
OK0846 # 08 Y:2013 | 08 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,202 | $862 | Implemented |
OK0846 # 09 Y:2013 | 09 | 2013 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $493 | $413 | Implemented |
GT0881 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,620 | $15,500 | Implemented |
GT0881 # 02 Y:2011 | 02 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,731 | $0 | Not Implemented |
GT0881 # 03 Y:2011 | 03 | 2011 | INSTALL COMMON HEADER ON COMPRESSORS | $2,800 | $3,200 | Not Implemented |
GT0881 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,921 | $21,722 | Not Implemented |
GT0881 # 05 Y:2011 | 05 | 2011 | DISCONNECT BALLASTS | $588 | $0 | Not Implemented |
GT0881 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,188 | $38,276 | Not Implemented |
GT0881 # 07 Y:2011 | 07 | 2011 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $38,551 | $150,000 | Not Implemented |
GT0881 # 08 Y:2011 | 08 | 2011 | COMBINE UTILITY METERS | $14,342 | $10,000 | Implemented |
OK0801 # 01 Y:2010 | 01 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $6,511 | $78,169 | Implemented |
OK0801 # 02 Y:2010 | 02 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,599 | $34,948 | Implemented |
OK0801 # 03 Y:2010 | 03 | 2010 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $9,699 | $3,000 | Implemented |
OK0801 # 04 Y:2010 | 04 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $995 | $2,625 | Implemented |
OK0801 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,205 | $660 | Not Implemented |
OK0801 # 06 Y:2010 | 06 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $523 | $516 | Not Implemented |
OK0801 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,015 | $2,017 | Not Implemented |
OK0801 # 08 Y:2010 | 08 | 2010 | INSTALL OCCUPANCY SENSORS | $547 | $1,658 | Not Implemented |