Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
223
matching recommendationsNAICS | 3371 | Household and Institutional Furniture and Kitchen Cabinet Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0498 # 08 Y:2013 | 08 | 2013 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $402 | $1,500 | Implemented |
NC0498 # 09 Y:2013 | 09 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,666 | $1,200 | Implemented |
NC0498 # 10 Y:2013 | 10 | 2013 | REPAIR OR REPLACE STEAM TRAPS | $9,172 | $6,200 | Implemented |
NC0498 # 11 Y:2013 | 11 | 2013 | BURN A LESS EXPENSIVE GRADE OF FUEL | $37,017 | $50,000 | Implemented |
NC0498 # 12 Y:2013 | 12 | 2013 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,038 | $1,000 | Not Implemented |
NC0498 # 13 Y:2013 | 13 | 2013 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,038 | $1,000 | Not Implemented |
NC0498 # 14 Y:2013 | 14 | 2013 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $12,483 | $61,250 | Not Implemented |
NC0494 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,160 | $7,564 | Not Implemented |
NC0494 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $1,833 | $1,524 | Not Implemented |
NC0494 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $195 | $61 | Not Implemented |
NC0494 # 04 Y:2013 | 04 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,051 | $825 | Not Implemented |
NC0494 # 05 Y:2013 | 05 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $950 | $4,258 | Not Implemented |
NC0494 # 06 Y:2013 | 06 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $856 | $820 | Not Implemented |
NC0494 # 07 Y:2013 | 07 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $410 | $100 | Not Implemented |
NC0495 # 01 Y:2013 | 01 | 2013 | INSTALL OCCUPANCY SENSORS | $1,753 | $5,222 | Not Implemented |
NC0495 # 02 Y:2013 | 02 | 2013 | ADD AREA LIGHTING SWITCHES | $3,238 | $1,650 | Not Implemented |
NC0495 # 03 Y:2013 | 03 | 2013 | USE PHOTOCELL CONTROLS | $4,114 | $7,500 | Not Implemented |
NC0495 # 04 Y:2013 | 04 | 2013 | USE PHOTOCELL CONTROLS | $615 | $3,797 | Not Implemented |
NC0495 # 05 Y:2013 | 05 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,495 | $1,041 | Not Implemented |
NC0495 # 06 Y:2013 | 06 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $813 | $3,663 | Not Implemented |
NC0495 # 07 Y:2013 | 07 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,730 | $60,000 | Not Implemented |
NC0495 # 08 Y:2013 | 08 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $748 | $100 | Not Implemented |
NC0495 # 09 Y:2013 | 09 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $123 | $600 | Not Implemented |
NC0495 # 10 Y:2013 | 10 | 2013 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,400 | $100 | Not Implemented |
NC0469 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,713 | $129,851 | Implemented |