IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

45

matching recommendations
Reset
NAICS 3371 Household and Institutional Furniture and Kitchen Cabinet Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0383 # 06 Y:2011 06 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $757 $281 Implemented
MS0383 # 05 Y:2011 05 2011 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,584 $659 Not Implemented
MS0383 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,247 $33,997 Implemented
MS0383 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,458 $26,246 Implemented
MS0383 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,874 $139,671 Implemented
MS0383 # 01 Y:2011 01 2011 RECOVER WASTE HEAT FROM EQUIPMENT $7,135 $6,411 Not Implemented
LE0324 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,830 $28,998 Not Implemented
LE0324 # 02 Y:2011 02 2011 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $8,133 $5,085 Not Implemented
LE0324 # 08 Y:2011 08 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $297 $530 Not Implemented
LE0324 # 01 Y:2011 01 2011 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $8,284 $122,400 Not Implemented
LE0324 # 06 Y:2011 06 2011 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS $2,832 $7,000 Not Implemented
LE0324 # 05 Y:2011 05 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,126 $26,983 Not Implemented
LE0324 # 04 Y:2011 04 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,665 $400 Not Implemented
LE0324 # 07 Y:2011 07 2011 INSTALL OCCUPANCY SENSORS $1,778 $416 Not Implemented
MS0376 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,815 $9,337 Implemented
MS0376 # 06 Y:2011 06 2011 INSTALL OCCUPANCY SENSORS $1,057 $471 Not Implemented
MS0376 # 05 Y:2011 05 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,005 $953 Not Implemented
MS0376 # 04 Y:2011 04 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,513 $1,725 Not Implemented
MS0376 # 02 Y:2011 02 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,694 $516 Implemented
MS0376 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,895 $53,390 Implemented
UM0385 # 03 Y:2011 03 2011 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $18,202 $11,500 Not Implemented
UM0385 # 05 Y:2011 05 2011 BURN WOOD BY-PRODUCTS FOR HEAT $6,704 $78,500 Not Implemented
UM0385 # 07 Y:2011 07 2011 RECOVER WASTE HEAT FROM EQUIPMENT $48,155 $21,000 Not Implemented
UM0385 # 01 Y:2011 01 2011 UPGRADE CONTROLS ON COMPRESSORS $1,423 $3,996 Implemented
UM0385 # 02 Y:2011 02 2011 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $390 $10 Not Implemented