Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
736
matching recommendationsNAICS | 33712 | Household and Institutional Furniture Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0509 # 01 Y:2014 | 01 | 2014 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,707 | $1,000 | Implemented |
NC0509 # 02 Y:2014 | 02 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,152 | $157 | Implemented |
NC0509 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,187 | $1,625 | Implemented |
NC0509 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $411 | $697 | Implemented |
NC0509 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $798 | $3,231 | Not Implemented |
NC0509 # 06 Y:2014 | 06 | 2014 | INSULATE FEEDWATER TANK | $198 | $75 | Implemented |
NC0509 # 07 Y:2014 | 07 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $792 | $787 | Not Implemented |
NC0509 # 08 Y:2014 | 08 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $585 | $50 | Not Implemented |
NC0509 # 09 Y:2014 | 09 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $725 | $450 | Implemented |
NC0509 # 10 Y:2014 | 10 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $270 | $100 | Implemented |
NC0509 # 11 Y:2014 | 11 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $85 | $105 | Implemented |
UA0113 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $47,063 | $93,733 | Not Implemented |
UA0113 # 02 Y:2014 | 02 | 2014 | INSTALL SKYLIGHTS | $31,556 | $40,622 | Not Implemented |
UA0113 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,580 | $1,900 | Implemented |
UA0113 # 04 Y:2014 | 04 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,732 | $800 | Not Implemented |
UA0113 # 05 Y:2014 | 05 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $10,526 | $11,550 | Not Implemented |
UA0113 # 06 Y:2014 | 06 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,556 | $321 | Implemented |
NC0496 # 01 Y:2013 | 01 | 2013 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,814 | $0 | Implemented |
NC0496 # 02 Y:2013 | 02 | 2013 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $21,698 | $75,000 | Not Implemented |
NC0496 # 03 Y:2013 | 03 | 2013 | CLOSE OFF UNNEEDED STEAM LINES | $638 | $0 | Implemented |
NC0496 # 04 Y:2013 | 04 | 2013 | REDUCE FLUID FLOW RATES | $698 | $3,000 | Implemented |
NC0496 # 05 Y:2013 | 05 | 2013 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $1,899 | $7,281 | Not Implemented |
NC0496 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,131 | $100 | Implemented |
NC0496 # 07 Y:2013 | 07 | 2013 | INSTALL OCCUPANCY SENSORS | $1,315 | $3,203 | Implemented |
NC0496 # 08 Y:2013 | 08 | 2013 | USE PHOTOCELL CONTROLS | $575 | $200 | Implemented |