Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

229

matching recommendations
Reset
NAICS 33712 Household and Institutional Furniture Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0561 # 02 Y:2016 02 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,608 $100 Implemented
NC0561 # 03 Y:2016 03 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,361 $200 Implemented
NC0561 # 04 Y:2016 04 2016 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $552 $1,500 Implemented
NC0561 # 11 Y:2016 11 2016 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $813 $281 Implemented
NC0561 # 10 Y:2016 10 2016 DEVELOP A REPAIR/REPLACE POLICY $977 $4,256 Implemented
NC0561 # 09 Y:2016 09 2016 TURN OFF EQUIPMENT WHEN NOT IN USE $2,806 $4,000 Implemented
NC0561 # 08 Y:2016 08 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $863 $300 Implemented
NC0561 # 07 Y:2016 07 2016 INSTALL OCCUPANCY SENSORS $1,138 $1,215 Not Implemented
NC0561 # 06 Y:2016 06 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,769 $32,929 Implemented
NC0561 # 05 Y:2016 05 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $48,868 $143,752 Implemented
NC0533 # 01 Y:2015 01 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,228 $6,494 Implemented
NC0533 # 02 Y:2015 02 2015 USE PHOTOCELL CONTROLS $253 $600 Implemented
NC0533 # 03 Y:2015 03 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $567 $100 Not Implemented
NC0533 # 04 Y:2015 04 2015 RECOVER WASTE HEAT FROM EQUIPMENT $751 $3,000 Not Implemented
NC0533 # 05 Y:2015 05 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $384 $100 Implemented
NC0533 # 06 Y:2015 06 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $254 $450 Implemented
NC0533 # 07 Y:2015 07 2015 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $571 $2,500 Not Implemented
NC0526 # 10 Y:2014 10 2014 INSTALL OCCUPANCY SENSORS $1,371 $5,355 Not Implemented
NC0526 # 02 Y:2014 02 2014 INCREASE AMOUNT OF CONDENSATE RETURNED $4,271 $2,400 Implemented
NC0526 # 09 Y:2014 09 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $343 $240 Implemented
NC0526 # 08 Y:2014 08 2014 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,294 $1,438 Not Implemented
NC0526 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,791 $8,593 Implemented
NC0526 # 06 Y:2014 06 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $134 $150 Not Implemented
NC0526 # 05 Y:2014 05 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $576 $100 Implemented
NC0526 # 11 Y:2014 11 2014 DEVELOP A REPAIR/REPLACE POLICY $561 $2,577 Implemented