Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsNAICS | 3372 | Office Furniture (including Fixtures) Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0500 # 03 Y:2013 | 03 | 2013 | AIR CONDITION ONLY SPACE NECESSARY | $4,146 | $200 | Implemented |
NC0500 # 13 Y:2013 | 13 | 2013 | INSTALL OCCUPANCY SENSORS | $596 | $1,565 | Not Implemented |
NC0500 # 12 Y:2013 | 12 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,622 | $775 | Implemented |
NC0500 # 11 Y:2013 | 11 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $456 | $2,704 | Not Implemented |
NC0500 # 10 Y:2013 | 10 | 2013 | METER WASTE WATER | $4,155 | $4,200 | Implemented |
NC0500 # 09 Y:2013 | 09 | 2013 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $286 | $750 | Not Implemented |
NC0500 # 08 Y:2013 | 08 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,389 | $7,000 | Implemented |
NC0500 # 07 Y:2013 | 07 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $577 | $875 | Implemented |
NC0500 # 06 Y:2013 | 06 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,293 | $125 | Implemented |
NC0500 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,558 | $100 | Implemented |
NC0500 # 04 Y:2013 | 04 | 2013 | REDUCE FLUID FLOW RATES | $34,287 | $18,000 | Implemented |
NC0500 # 02 Y:2013 | 02 | 2013 | MAKE A NEW BY-PRODUCT | $86,815 | $250,000 | Implemented |
NC0500 # 01 Y:2013 | 01 | 2013 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $59,689 | $250,000 | Not Implemented |
UA0094 # 01 Y:2013 | 01 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $52,762 | $41,601 | Implemented |
UA0094 # 09 Y:2013 | 09 | 2013 | OPTIMIZE PLANT POWER FACTOR | $6,000 | $14,980 | Not Implemented |
UA0094 # 08 Y:2013 | 08 | 2013 | DISCONNECT BALLASTS | $13,800 | $8,100 | Implemented |
UA0094 # 07 Y:2013 | 07 | 2013 | INSULATE BARE EQUIPMENT | $7,049 | $12,413 | Not Implemented |
UA0094 # 06 Y:2013 | 06 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $6,212 | $16,350 | Implemented |
UA0094 # 05 Y:2013 | 05 | 2013 | BURN WOOD BY-PRODUCTS FOR HEAT | $290,469 | $297,000 | Not Implemented |
UA0094 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,674 | $4,500 | Implemented |
UA0094 # 03 Y:2013 | 03 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,165 | $800 | Implemented |
UA0094 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,672 | $4,500 | Implemented |