Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
564
matching recommendationsNAICS | 33721 | Office Furniture (including Fixtures) Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0005 # 01 Y:2012 | 01 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,565 | $1,150 | Not Implemented |
WM0005 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $1,819 | $200 | Implemented |
WM0005 # 03 Y:2012 | 03 | 2012 | INSTALL SKYLIGHTS | $2,119 | $4,205 | Not Implemented |
WM0005 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $365 | $2,000 | Implemented |
WM0005 # 05 Y:2012 | 05 | 2012 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,321 | $95 | Implemented |
WM0005 # 06 Y:2012 | 06 | 2012 | RECOVER AND REUSE WASTE MATERIAL | $27,546 | $9,000 | Not Implemented |
WM0005 # 07 Y:2012 | 07 | 2012 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $982 | $3,646 | Implemented |
NC0450 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $31,614 | $21,400 | Implemented |
NC0450 # 02 Y:2012 | 02 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,614 | $9,225 | Not Implemented |
NC0450 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,109 | $100 | Implemented |
NC0450 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,655 | $98,739 | Implemented |
NC0450 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,286 | $973 | Implemented |
NC0450 # 06 Y:2012 | 06 | 2012 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $632 | $2,035 | Not Implemented |
NC0450 # 07 Y:2012 | 07 | 2012 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $113,534 | $25,000 | Implemented |
NC0450 # 08 Y:2012 | 08 | 2012 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $105,000 | $40,000 | Implemented |
NC0450 # 09 Y:2012 | 09 | 2012 | MAINTAIN CLEAN CONDITIONS BEFORE PAINTING | $38,389 | $30,000 | Implemented |
NC0450 # 10 Y:2012 | 10 | 2012 | IMPROVE SPACE COMFORT CONDITIONING | $4,739 | $8,000 | Not Implemented |
SD0507 # 01 Y:2011 | 01 | 2011 | USE PHOTOCELL CONTROLS | $152 | $0 | Implemented |
SD0507 # 02 Y:2011 | 02 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,615 | $5,000 | Not Implemented |
SD0507 # 03 Y:2011 | 03 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,820 | $2,500 | Not Implemented |
SD0507 # 04 Y:2011 | 04 | 2011 | INSULATE FEEDWATER TANK | $443 | $400 | Not Implemented |
SD0507 # 05 Y:2011 | 05 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,758 | $7,385 | Not Implemented |
SD0507 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $515 | $983 | Implemented |
SD0433 # 01 Y:2011 | 01 | 2011 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $119 | $10 | Not Implemented |
SD0433 # 02 Y:2011 | 02 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $881 | $300 | Implemented |