Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

564

matching recommendations
Reset
NAICS 33721 Office Furniture (including Fixtures) Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0393 # 07 Y:2006 07 2006 INSTALL OCCUPANCY SENSORS $636 $1,155 Implemented
IA0393 # 08 Y:2006 08 2006 MODIFY STARTUP/SHUTDOWN TIMES $5,715 $0 Implemented
WV0336 # 01 Y:2006 01 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,594 $14,968 Implemented
WV0336 # 02 Y:2006 02 2006 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $14,092 $25,000 Not Implemented
WV0336 # 03 Y:2006 03 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,454 $1,333 Implemented
WV0336 # 04 Y:2006 04 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,755 $0 Implemented
WV0336 # 05 Y:2006 05 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,345 $0 Implemented
WV0336 # 06 Y:2006 06 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,097 $510 Not Implemented
WV0336 # 07 Y:2006 07 2006 DEVELOP A REPAIR/REPLACE POLICY $2,688 $231 Implemented
WV0336 # 08 Y:2006 08 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $796 $189 Implemented
WV0336 # 09 Y:2006 09 2006 UTILIZE A LESS EXPENSIVE COOLING METHOD $320 $0 Not Implemented
WV0334 # 01 Y:2006 01 2006 USE RADIANT HEATER FOR SPOT HEATING $50,392 $80,000 Not Implemented
WV0334 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,971 $13,343 Implemented
WV0334 # 03 Y:2006 03 2006 OPTIMIZE PLANT POWER FACTOR $20,449 $12,020 Implemented
WV0334 # 04 Y:2006 04 2006 DEVELOP A REPAIR/REPLACE POLICY $11,461 $648 Implemented
WV0334 # 05 Y:2006 05 2006 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,398 $350 Implemented
WV0334 # 06 Y:2006 06 2006 REDUCE VENTILATION AIR $3,560 $892 Implemented
WV0334 # 07 Y:2006 07 2006 INSTALL OCCUPANCY SENSORS $2,103 $473 Implemented
WV0334 # 08 Y:2006 08 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,543 $650 Implemented
WV0334 # 09 Y:2006 09 2006 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,275 $2,748 Implemented
WV0334 # 10 Y:2006 10 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,226 $0 Implemented
WV0334 # 11 Y:2006 11 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $874 $145 Implemented
WV0334 # 12 Y:2006 12 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $401 $170 Implemented
LM0105 # 01 Y:2006 01 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $638 $0 Not Implemented
LM0105 # 02 Y:2006 02 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,156 $960 Implemented