Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
72
matching recommendationsNAICS | 339 | Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0083 # 06 Y:2012 | 06 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $1,585 | $3,212 | Not Implemented |
UA0068 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $1,210 | $2,719 | Not Implemented |
UA0068 # 05 Y:2011 | 05 | 2011 | DISCONNECT BALLASTS | $3,015 | $607 | Not Implemented |
UA0068 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,451 | $46,341 | Implemented |
UA0068 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,210 | $4,238 | Not Implemented |
UA0068 # 02 Y:2011 | 02 | 2011 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $15,438 | $13,988 | Implemented |
UA0068 # 01 Y:2011 | 01 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $16,400 | $5,100 | Implemented |
UA0055 # 10 Y:2010 | 10 | 2010 | INSTALL OCCUPANCY SENSORS | $559 | $387 | Not Implemented |
UA0055 # 12 Y:2010 | 12 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $114 | $250 | Not Implemented |
UA0055 # 11 Y:2010 | 11 | 2010 | DISCONNECT BALLASTS | $123 | $80 | Implemented |
UA0055 # 09 Y:2010 | 09 | 2010 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $341 | $106 | Not Implemented |
UA0055 # 08 Y:2010 | 08 | 2010 | USE PHOTOCELL CONTROLS | $983 | $354 | Not Implemented |
UA0055 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,014 | $1,500 | Implemented |
UA0055 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,545 | $640 | Not Implemented |
UA0055 # 05 Y:2010 | 05 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $3,444 | $1,970 | Not Implemented |
UA0055 # 04 Y:2010 | 04 | 2010 | INSULATE BARE EQUIPMENT | $14,550 | $5,020 | Not Implemented |
UA0055 # 03 Y:2010 | 03 | 2010 | USE MINIMUM SAFE OVEN VENTILATION | $4,422 | $990 | Not Implemented |
UA0055 # 02 Y:2010 | 02 | 2010 | USE OPTIMUM THICKNESS INSULATION | $12,398 | $1,602 | Not Implemented |
UA0055 # 01 Y:2010 | 01 | 2010 | USE OPTIMUM TEMPERATURE | $30,674 | $1,072 | Implemented |
UA0024 # 05 Y:2008 | 05 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $6,203 | $300 | Implemented |
UA0024 # 09 Y:2008 | 09 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $42,744 | $45,700 | Not Implemented |
UA0024 # 04 Y:2008 | 04 | 2008 | DISCONNECT BALLASTS | $1,392 | $243 | Implemented |
UA0024 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,199 | $14,155 | Not Implemented |
UA0024 # 08 Y:2008 | 08 | 2008 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $24,566 | $23,000 | Not Implemented |
UA0024 # 07 Y:2008 | 07 | 2008 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $98,000 | $126,000 | Not Implemented |