Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
111
matching recommendationsNAICS | 339 | Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0368 # 09 Y:2020 | 09 | 2020 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $626 | $1,661 | Implemented |
MI0368 # 08 Y:2020 | 08 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $663 | $1,980 | Implemented |
MI0368 # 07 Y:2020 | 07 | 2020 | UPGRADE CONTROLS ON COMPRESSORS | $1,717 | $3,320 | Implemented |
MI0368 # 01 Y:2020 | 01 | 2020 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $31,298 | $16,924 | Implemented |
MI0368 # 02 Y:2020 | 02 | 2020 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $13,791 | $2,940 | Not Implemented |
MI0368 # 03 Y:2020 | 03 | 2020 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $8,339 | $39,554 | Implemented |
MI0368 # 04 Y:2020 | 04 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,279 | $10,827 | Implemented |
MI0368 # 05 Y:2020 | 05 | 2020 | INSTALL OCCUPANCY SENSORS | $3,930 | $1,355 | Implemented |
MI0368 # 06 Y:2020 | 06 | 2020 | OPTIMIZE PLANT POWER FACTOR | $2,326 | $1,672 | Implemented |
MI0352 # 12 Y:2019 | 12 | 2019 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $518 | $2,294 | Implemented |
MI0352 # 11 Y:2019 | 11 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $525 | $160 | Not Implemented |
MI0352 # 10 Y:2019 | 10 | 2019 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $603 | $2,315 | Implemented |
MI0352 # 09 Y:2019 | 09 | 2019 | INSTALL OCCUPANCY SENSORS | $656 | $319 | Implemented |
MI0352 # 08 Y:2019 | 08 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,571 | $1,995 | Not Implemented |
MI0352 # 07 Y:2019 | 07 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,851 | $1,846 | Implemented |
MI0352 # 06 Y:2019 | 06 | 2019 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,012 | $100 | Implemented |
MI0352 # 05 Y:2019 | 05 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,725 | $2,284 | Implemented |
MI0352 # 04 Y:2019 | 04 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,201 | $7,920 | Implemented |
MI0352 # 03 Y:2019 | 03 | 2019 | USE SOLAR HEAT TO HEAT WATER | $7,116 | $10,125 | Implemented |
MI0352 # 02 Y:2019 | 02 | 2019 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,207 | $3,600 | Implemented |
MI0352 # 01 Y:2019 | 01 | 2019 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $15,430 | $10,964 | Implemented |
MI0342 # 03 Y:2018 | 03 | 2018 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $32,500 | $15,000 | Implemented |
MI0342 # 07 Y:2018 | 07 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $770 | $80 | Implemented |
MI0342 # 04 Y:2018 | 04 | 2018 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $15,291 | $14,298 | Implemented |
MI0342 # 06 Y:2018 | 06 | 2018 | OPTIMIZE PLANT POWER FACTOR | $3,475 | $14,430 | Not Implemented |