Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,372
matching recommendationsNAICS | 3399 | Other Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0258 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $491 | $469 | Implemented |
SU0258 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,446 | $4,400 | Implemented |
SU0258 # 11 Y:2007 | 11 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,915 | $2,847 | Not Implemented |
SU0258 # 12 Y:2007 | 12 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $197 | $344 | Not Implemented |
SU0258 # 13 Y:2007 | 13 | 2007 | INSTALL OCCUPANCY SENSORS | $112 | $357 | Implemented |
SU0258 # 14 Y:2007 | 14 | 2007 | OPTIMIZE PLANT POWER FACTOR | $1,080 | $9,965 | Not Implemented |
UA0006 # 01 Y:2007 | 01 | 2007 | USE PHOTOCELL CONTROLS | $112 | $36 | Not Implemented |
UA0006 # 02 Y:2007 | 02 | 2007 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $2,561 | $1,023 | Not Implemented |
UA0006 # 03 Y:2007 | 03 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $40 | $10 | Not Implemented |
UA0006 # 04 Y:2007 | 04 | 2007 | DISCONNECT BALLASTS | $497 | $216 | Implemented |
UA0006 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $358 | $276 | Implemented |
UA0006 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $120 | $0 | Implemented |
WV0360 # 01 Y:2007 | 01 | 2007 | ADJUST BURNERS FOR EFFICIENT OPERATION | $48,535 | $170,000 | Not Implemented |
WV0360 # 02 Y:2007 | 02 | 2007 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $44,169 | $15,000 | Not Implemented |
WV0360 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,939 | $70,000 | Not Implemented |
WV0360 # 04 Y:2007 | 04 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,938 | $700 | Implemented |
WV0360 # 05 Y:2007 | 05 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $5,516 | $1,900 | Implemented |
WV0360 # 06 Y:2007 | 06 | 2007 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $5,399 | $1,000 | Implemented |
WV0360 # 07 Y:2007 | 07 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,158 | $400 | Not Implemented |
WV0360 # 08 Y:2007 | 08 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,676 | $3,700 | Implemented |
WV0360 # 09 Y:2007 | 09 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,188 | $25 | Implemented |
WV0360 # 10 Y:2007 | 10 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,930 | $300 | Implemented |
WV0360 # 11 Y:2007 | 11 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,426 | $900 | Implemented |
SU0248 # 01 Y:2007 | 01 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,292 | $0 | Not Implemented |
SU0248 # 02 Y:2007 | 02 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,903 | $0 | Not Implemented |