Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,372
matching recommendationsNAICS | 3399 | Other Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0378 # 06 Y:2006 | 06 | 2006 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $55,146 | $7,392 | Not Implemented |
UF0378 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,845 | $12,045 | Implemented |
UF0378 # 08 Y:2006 | 08 | 2006 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $3,397 | $507 | Implemented |
LM0112 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $615 | $200 | Implemented |
LM0112 # 02 Y:2006 | 02 | 2006 | ADJUST VENTS TO MINIMIZE ENERGY USE | $19,700 | $0 | Not Implemented |
LM0112 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,130 | $8,728 | Implemented |
LM0112 # 04 Y:2006 | 04 | 2006 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $433,948 | $1,000 | Not Implemented |
LM0112 # 05 Y:2006 | 05 | 2006 | MODIFY STARTUP/SHUTDOWN TIMES | $10,000 | $0 | Not Implemented |
LM0112 # 06 Y:2006 | 06 | 2006 | ADD ADDITIONAL PRODUCTION SHIFT | $1,348 | $0 | Implemented |
UF0375 # 01 Y:2006 | 01 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,929 | $15,889 | Not Implemented |
UF0375 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,307 | $33,550 | Not Implemented |
UF0375 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $85,158 | $3,540 | Implemented |
UF0375 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,627 | $180 | Implemented |
UF0375 # 05 Y:2006 | 05 | 2006 | OPTIMIZE PLANT POWER FACTOR | $129,429 | $17,000 | Implemented |
UF0375 # 06 Y:2006 | 06 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $15,443 | $49,050 | Not Implemented |
UF0375 # 07 Y:2006 | 07 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $12,590 | $0 | Implemented |
UF0375 # 08 Y:2006 | 08 | 2006 | DISCONNECT BALLASTS | $2,018 | $0 | Implemented |
UF0375 # 09 Y:2006 | 09 | 2006 | INSTALL BACK-UP EQUIPMENT | $1,160,914 | $79,825 | Not Implemented |
UD0735 # 01 Y:2006 | 01 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $212,325 | $9,000 | Implemented |
UD0735 # 02 Y:2006 | 02 | 2006 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $36,368 | $5,000 | Not Implemented |
UD0735 # 03 Y:2006 | 03 | 2006 | RECOVER MECHANICAL ENERGY | $33,450 | $32 | Implemented |
UD0735 # 04 Y:2006 | 04 | 2006 | REDUCE VENTILATION AIR | $38,385 | $0 | Not Implemented |
UD0735 # 05 Y:2006 | 05 | 2006 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $14,908 | $5,056 | Not Implemented |
UD0735 # 06 Y:2006 | 06 | 2006 | DISCONNECT BALLASTS | $9,527 | $1,440 | Implemented |
UD0735 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $5,203 | $21,789 | Implemented |