Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
161
matching recommendationsNAICS | 33992 | Sporting and Athletic Goods Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0139 # 03 Y:2014 | 03 | 2014 | USE PHOTOCELL CONTROLS | $4,586 | $2,450 | Implemented |
MZ0139 # 04 Y:2014 | 04 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $13,499 | $0 | Not Implemented |
MZ0139 # 05 Y:2014 | 05 | 2014 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,210 | $0 | Implemented |
MZ0139 # 06 Y:2014 | 06 | 2014 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $60,368 | $50,000 | Implemented |
MZ0139 # 07 Y:2014 | 07 | 2014 | CONDENSE OPERATION INTO ONE BUILDING | $16,179 | $85,000 | Implemented |
MZ0139 # 08 Y:2014 | 08 | 2014 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,370 | $40,000 | Not Implemented |
WM0037 # 01 Y:2013 | 01 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $92 | $51 | Not Implemented |
WM0037 # 02 Y:2013 | 02 | 2013 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $417 | $390 | Not Implemented |
WM0037 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $115 | $273 | Not Implemented |
WM0037 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $314 | $200 | Not Implemented |
WM0037 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $427 | $0 | Not Implemented |
WM0037 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $168 | $205 | Implemented |
WM0037 # 07 Y:2013 | 07 | 2013 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,533 | $800 | Not Implemented |
WM0037 # 08 Y:2013 | 08 | 2013 | USE PHOTOCELL CONTROLS | $370 | $1,800 | Not Implemented |
WM0037 # 09 Y:2013 | 09 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $678 | $3,225 | Not Implemented |
WM0037 # 10 Y:2013 | 10 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $83 | $0 | Not Implemented |
WM0037 # 11 Y:2013 | 11 | 2013 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,347 | $647 | Not Implemented |
WM0037 # 12 Y:2013 | 12 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $687 | $900 | Not Implemented |
WM0037 # 13 Y:2013 | 13 | 2013 | MODIFY WORKLOAD | $21,420 | $3,781 | Not Implemented |
AM0648 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $52,176 | $5,000 | Implemented |
AM0648 # 02 Y:2013 | 02 | 2013 | RECYCLE WASTE INK AND CLEANUP SOLVENT | $29,607 | $0 | Implemented |
AM0648 # 03 Y:2013 | 03 | 2013 | OPTIMIZE PLANT POWER FACTOR | $16,856 | $22,350 | Implemented |
AM0648 # 04 Y:2013 | 04 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $10,740 | $0 | Implemented |
AM0648 # 05 Y:2013 | 05 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $10,304 | $45,000 | Implemented |
AM0648 # 06 Y:2013 | 06 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $9,059 | $167 | Implemented |