Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
906
matching recommendationsNAICS | 33999 | All Other Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0248 # 10 Y:2007 | 10 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,967 | $4,730 | Not Implemented |
SU0248 # 11 Y:2007 | 11 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,423 | $2,030 | Not Implemented |
SU0248 # 12 Y:2007 | 12 | 2007 | INSTALL OCCUPANCY SENSORS | $566 | $823 | Implemented |
SU0248 # 13 Y:2007 | 13 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $89 | $135 | Implemented |
UD0748 # 01 Y:2006 | 01 | 2006 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $432,000 | $143,750 | Not Implemented |
UD0748 # 02 Y:2006 | 02 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,546 | $0 | Implemented |
UD0748 # 03 Y:2006 | 03 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,200 | $840 | Implemented |
UD0748 # 04 Y:2006 | 04 | 2006 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,988 | $2,960 | Not Implemented |
UD0748 # 05 Y:2006 | 05 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $303 | $108 | Implemented |
MS0297 # 01 Y:2006 | 01 | 2006 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $45,413 | $160,000 | Not Implemented |
MS0297 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,548 | $26,994 | Not Implemented |
MS0297 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,825 | $225 | Implemented |
MS0297 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,005 | $7,451 | Not Implemented |
LM0112 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $615 | $200 | Implemented |
LM0112 # 02 Y:2006 | 02 | 2006 | ADJUST VENTS TO MINIMIZE ENERGY USE | $19,700 | $0 | Not Implemented |
LM0112 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,130 | $8,728 | Implemented |
LM0112 # 04 Y:2006 | 04 | 2006 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $433,948 | $1,000 | Not Implemented |
LM0112 # 05 Y:2006 | 05 | 2006 | MODIFY STARTUP/SHUTDOWN TIMES | $10,000 | $0 | Not Implemented |
LM0112 # 06 Y:2006 | 06 | 2006 | ADD ADDITIONAL PRODUCTION SHIFT | $1,348 | $0 | Implemented |
UD0735 # 01 Y:2006 | 01 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $212,325 | $9,000 | Implemented |
UD0735 # 02 Y:2006 | 02 | 2006 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $36,368 | $5,000 | Not Implemented |
UD0735 # 03 Y:2006 | 03 | 2006 | RECOVER MECHANICAL ENERGY | $33,450 | $32 | Implemented |
UD0735 # 04 Y:2006 | 04 | 2006 | REDUCE VENTILATION AIR | $38,385 | $0 | Not Implemented |
UD0735 # 05 Y:2006 | 05 | 2006 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $14,908 | $5,056 | Not Implemented |
UD0735 # 06 Y:2006 | 06 | 2006 | DISCONNECT BALLASTS | $9,527 | $1,440 | Implemented |