Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

190

matching recommendations
Reset
NAICS 424 Merchant Wholesalers, Nondurable Goods
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0538 # 03 Y:2008 03 2008 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $433,305 $300,000 Not Implemented
OR0538 # 04 Y:2008 04 2008 INSTALL SENSORS TO DETECT DEFECTS $132,288 $140,000 Not Implemented
OR0538 # 05 Y:2008 05 2008 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $9,546 $7,085 Not Implemented
OR0538 # 06 Y:2008 06 2008 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $16,035 $16,204 Not Implemented
LE0276 # 01 Y:2008 01 2008 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $144,000 $92,000 Implemented
LE0276 # 02 Y:2008 02 2008 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $55,360 $30,000 Not Implemented
LE0276 # 03 Y:2008 03 2008 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $38,127 $30,600 Not Implemented
LE0276 # 04 Y:2008 04 2008 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $18,230 $16,000 Implemented
LE0276 # 05 Y:2008 05 2008 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $15,550 $500 Not Implemented
LE0276 # 06 Y:2008 06 2008 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $10,749 $16,800 Not Implemented
LE0276 # 07 Y:2008 07 2008 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $1,838 $3,600 Not Implemented
LE0276 # 08 Y:2008 08 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $36,479 $53,518 Not Implemented
LE0276 # 09 Y:2008 09 2008 INSTALL OCCUPANCY SENSORS $12,548 $600 Not Implemented
TT0008 # 01 Y:2007 01 2007 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $930 $2,000 Not Implemented
TT0008 # 02 Y:2007 02 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $345 $110 Implemented
TT0008 # 03 Y:2007 03 2007 INSULATE BARE EQUIPMENT $1,200 $300 Implemented
TT0008 # 04 Y:2007 04 2007 INCREASE AMOUNT OF CONDENSATE RETURNED $741 $350 Not Implemented
TT0008 # 05 Y:2007 05 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,000 $1,500 Not Implemented
TT0008 # 06 Y:2007 06 2007 INSULATE BARE EQUIPMENT $563 $100 Implemented
OR0518 # 01 Y:2007 01 2007 MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT $51,600 $120,000 Not Implemented
OR0518 # 02 Y:2007 02 2007 INSTALL OCCUPANCY SENSORS $1,020 $2,050 Implemented
OR0518 # 03 Y:2007 03 2007 INSULATE BARE EQUIPMENT $840 $4,100 Not Implemented
BD0328 # 01 Y:2007 01 2007 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $7,446 $2,400 Not Implemented
BD0328 # 02 Y:2007 02 2007 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,262 $14,000 Not Implemented
BD0328 # 03 Y:2007 03 2007 USE PHOTOCELL CONTROLS $1,823 $90 Not Implemented