IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

266

matching recommendations
Reset
NAICS 5111 Newspaper, Periodical, Book, and Directory Publishers
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0334 # 04 Y:2008 04 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,188 $1,520 Not Implemented
UM0334 # 05 Y:2008 05 2008 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,000 $700 Not Implemented
UM0334 # 06 Y:2008 06 2008 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $658 $1,110 Not Implemented
UM0334 # 07 Y:2008 07 2008 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $427 $500 Not Implemented
OK0757 # 01 Y:2008 01 2008 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,747 $1,256 Not Implemented
OK0757 # 02 Y:2008 02 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $14,252 $7,032 Not Implemented
OK0757 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,400 $39,500 Not Implemented
OK0757 # 04 Y:2008 04 2008 $9,419 $0 Not Implemented
OK0757 # 05 Y:2008 05 2008 RECOVER WASTE HEAT FROM EQUIPMENT $5,133 $4,638 Not Implemented
OK0757 # 06 Y:2008 06 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $958 $1,214 Not Implemented
MI0146 # 07 Y:2007 07 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,866 $2,373 Not Implemented
MI0146 # 02 Y:2007 02 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $37,375 $30 Implemented
MI0146 # 01 Y:2007 01 2007 UTILIZE A LESS EXPENSIVE COOLING METHOD $127,674 $105,070 Not Implemented
MI0146 # 06 Y:2007 06 2007 USE PHOTOCELL CONTROLS $6,838 $770 Not Implemented
MI0146 # 05 Y:2007 05 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $13,799 $14,700 Not Implemented
MI0146 # 04 Y:2007 04 2007 HEAT WATER WITH EXHAUST HEAT $14,461 $1,349 Implemented
MI0146 # 08 Y:2007 08 2007 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $1,920 $4,160 Not Implemented
MI0146 # 03 Y:2007 03 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,482 $1,074 Implemented
BD0294 # 02 Y:2005 02 2005 INSTALL OCCUPANCY SENSORS $1,291 $750 Not Implemented
BD0294 # 01 Y:2005 01 2005 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $7,821 $400 Implemented
BD0294 # 06 Y:2005 06 2005 $13,260 $2,000 Implemented
BD0294 # 07 Y:2005 07 2005 $8,840 $3,000 Implemented
BD0294 # 04 Y:2005 04 2005 $41,600 $22,000 Implemented
BD0294 # 05 Y:2005 05 2005 $40,952 $20,000 Implemented
BD0294 # 03 Y:2005 03 2005 INSULATE BARE EQUIPMENT $599 $263 Implemented