Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
13
matching recommendationsNAICS | 51111 | Newspaper Publishers |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0334 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,003 | $25,980 | Not Implemented |
UM0334 # 02 Y:2008 | 02 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,418 | $4,000 | Not Implemented |
UM0334 # 03 Y:2008 | 03 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,388 | $1,200 | Not Implemented |
UM0334 # 04 Y:2008 | 04 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,188 | $1,520 | Not Implemented |
UM0334 # 05 Y:2008 | 05 | 2008 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,000 | $700 | Not Implemented |
UM0334 # 06 Y:2008 | 06 | 2008 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $658 | $1,110 | Not Implemented |
UM0334 # 07 Y:2008 | 07 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $427 | $500 | Not Implemented |
OK0757 # 01 Y:2008 | 01 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,747 | $1,256 | Not Implemented |
OK0757 # 02 Y:2008 | 02 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,252 | $7,032 | Not Implemented |
OK0757 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,400 | $39,500 | Not Implemented |
OK0757 # 04 Y:2008 | 04 | 2008 | APPLY FOR INVESTMENT INCENTIVES | $9,419 | $0 | Not Implemented |
OK0757 # 05 Y:2008 | 05 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,133 | $4,638 | Not Implemented |
OK0757 # 06 Y:2008 | 06 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $958 | $1,214 | Not Implemented |