Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
49
matching recommendationsNAICS | 541380 | Testing Laboratories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0104 # 03 Y:2017 | 03 | 2017 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $14,165 | $0 | Implemented |
WM0104 # 02 Y:2017 | 02 | 2017 | OPTIMIZE PLANT POWER FACTOR | $15,927 | $33,500 | Not Implemented |
WM0104 # 01 Y:2017 | 01 | 2017 | STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS | $64,540 | $93,226 | Not Implemented |
UM0423 # 03 Y:2013 | 03 | 2013 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $4,300 | $6,500 | Not Implemented |
UM0423 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,224 | $5,550 | Implemented |
UM0423 # 01 Y:2013 | 01 | 2013 | INSTALL OCCUPANCY SENSORS | $454 | $175 | Implemented |
UM0393 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,125 | $29,225 | Implemented |
UM0393 # 01 Y:2011 | 01 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $25,825 | $18,696 | Implemented |
UM0393 # 12 Y:2011 | 12 | 2011 | INSULATE BARE EQUIPMENT | $12,938 | $600 | Implemented |
UM0393 # 11 Y:2011 | 11 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,143 | $2,500 | Not Implemented |
UM0393 # 10 Y:2011 | 10 | 2011 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $10,545 | $23,900 | Not Implemented |
UM0393 # 09 Y:2011 | 09 | 2011 | INSTALL OCCUPANCY SENSORS | $1,916 | $1,200 | Implemented |
UM0393 # 08 Y:2011 | 08 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,408 | $1,533 | Implemented |
UM0393 # 07 Y:2011 | 07 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,578 | $200 | Not Implemented |
UM0393 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,888 | $5,440 | Implemented |
UM0393 # 05 Y:2011 | 05 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $7,039 | $6,006 | Not Implemented |
UM0393 # 04 Y:2011 | 04 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,581 | $2,500 | Implemented |
UM0393 # 02 Y:2011 | 02 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,190 | $18,432 | Not Implemented |
SF0325 # 06 Y:2006 | 06 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,876 | $22,500 | Not Implemented |
SF0325 # 05 Y:2006 | 05 | 2006 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $15,438 | $8,485 | Not Implemented |
SF0325 # 04 Y:2006 | 04 | 2006 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,700 | $1,150 | Not Implemented |
SF0325 # 03 Y:2006 | 03 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $26,518 | $25,760 | Not Implemented |
SF0325 # 02 Y:2006 | 02 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $25,307 | $25,760 | Not Implemented |
SF0325 # 01 Y:2006 | 01 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,756 | $0 | Not Implemented |