Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
116
matching recommendationsNAICS | 551114 | Corporate, Subsidiary, and Regional Managing Offices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0324 # 01 Y:2025 | 01 | 2025 | USE SOLAR HEAT TO MAKE ELECTRICTY | $65,101 | $294,166 | n/a |
IC0323 # 05 Y:2025 | 05 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $497 | $1,045 | n/a |
IC0323 # 01 Y:2025 | 01 | 2025 | USE SOLAR HEAT TO MAKE ELECTRICTY | $47,182 | $233,599 | n/a |
IC0323 # 02 Y:2025 | 02 | 2025 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $549 | $2,512 | n/a |
IC0323 # 03 Y:2025 | 03 | 2025 | INSULATE BARE EQUIPMENT | $984 | $6,680 | n/a |
IC0323 # 06 Y:2025 | 06 | 2025 | REPLACE BOILER | $5,000 | $39,055 | n/a |
IC0323 # 07 Y:2025 | 07 | 2025 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $130 | $288 | n/a |
IC0323 # 04 Y:2025 | 04 | 2025 | INSTALL OCCUPANCY SENSORS | $6,567 | $6,783 | n/a |
IC0312 # 07 Y:2024 | 07 | 2024 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $2,161 | $0 | Not Implemented |
IC0312 # 06 Y:2024 | 06 | 2024 | ELIMINATE/REDUCE AN OPERATION | $70,893 | $0 | Not Implemented |
IC0312 # 05 Y:2024 | 05 | 2024 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,685 | $0 | Implemented |
IC0312 # 04 Y:2024 | 04 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $196,644 | $810,434 | Not Implemented |
IC0312 # 03 Y:2024 | 03 | 2024 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,867 | $1,676 | Not Implemented |
IC0312 # 02 Y:2024 | 02 | 2024 | INSTALL OCCUPANCY SENSORS | $43,524 | $26,950 | Implemented |
IC0312 # 01 Y:2024 | 01 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $70,425 | $212,126 | Implemented |
IC0311 # 03 Y:2024 | 03 | 2024 | INSTALL OCCUPANCY SENSORS | $39 | $215 | Implemented |
IC0310 # 02 Y:2024 | 02 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,362 | $3,159 | Not Implemented |
IC0310 # 03 Y:2024 | 03 | 2024 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $6,404 | $0 | Not Implemented |
IC0310 # 04 Y:2024 | 04 | 2024 | INSTALL OCCUPANCY SENSORS | $464 | $614 | Implemented |
IC0310 # 05 Y:2024 | 05 | 2024 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,515 | $419 | Not Implemented |
IC0310 # 06 Y:2024 | 06 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $344 | $625 | Implemented |
IC0310 # 07 Y:2024 | 07 | 2024 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,681 | $2,178 | Implemented |
IC0310 # 08 Y:2024 | 08 | 2024 | INSTALL TIMERS AND/OR THERMOSTATS | $3,945 | $1,100 | Not Implemented |
IC0310 # 09 Y:2024 | 09 | 2024 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $125 | $580 | Implemented |
IC0311 # 06 Y:2024 | 06 | 2024 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $844 | $140 | Not Implemented |