Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsNAICS | 61111 | Elementary and Secondary Schools |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0640 # 14 Y:2013 | 14 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,881 | $40 | Not Implemented |
AM0640 # 26 Y:2013 | 26 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $170 | $0 | Not Implemented |
AM0640 # 25 Y:2013 | 25 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $306 | $0 | Not Implemented |
AM0640 # 24 Y:2013 | 24 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $405 | $2,495 | Implemented |
AM0640 # 23 Y:2013 | 23 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $503 | $10 | Implemented |
AM0640 # 22 Y:2013 | 22 | 2013 | USE SYNTHETIC LUBRICANT | $660 | $0 | Not Implemented |
AM0640 # 21 Y:2013 | 21 | 2013 | MINIMIZE WATER USAGE | $772 | $460 | Implemented |
AM0640 # 20 Y:2013 | 20 | 2013 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $970 | $2,850 | Implemented |
AM0640 # 19 Y:2013 | 19 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $975 | $1,720 | Implemented |
AM0640 # 18 Y:2013 | 18 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,016 | $27 | Implemented |
AM0640 # 17 Y:2013 | 17 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,378 | $0 | Implemented |
AM0640 # 16 Y:2013 | 16 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,130 | $3,780 | Not Implemented |
AM0640 # 15 Y:2013 | 15 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,537 | $0 | Not Implemented |
AM0640 # 01 Y:2013 | 01 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $79,770 | $0 | Implemented |
AM0640 # 13 Y:2013 | 13 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,955 | $11,248 | Implemented |
AM0640 # 12 Y:2013 | 12 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,085 | $20 | Not Implemented |
AM0640 # 11 Y:2013 | 11 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,400 | $500 | Implemented |
AM0640 # 10 Y:2013 | 10 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,965 | $600 | Implemented |
AM0640 # 09 Y:2013 | 09 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,528 | $3,600 | Implemented |
AM0640 # 08 Y:2013 | 08 | 2013 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $6,079 | $840 | Implemented |
AM0640 # 07 Y:2013 | 07 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,323 | $1,040 | Not Implemented |
AM0640 # 06 Y:2013 | 06 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,738 | $10,800 | Implemented |
AM0640 # 05 Y:2013 | 05 | 2013 | REPLACE BOILER | $14,187 | $213,000 | Implemented |
AM0640 # 04 Y:2013 | 04 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $15,124 | $200,000 | Implemented |
AM0640 # 03 Y:2013 | 03 | 2013 | OPTIMIZE PLANT POWER FACTOR | $18,322 | $28,020 | Not Implemented |