IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

32

matching recommendations
Reset
NAICS 721110 Hotels (except Casino Hotels) and Motels
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LS2023 # 07 Y:2023 07 2023 IMPROVE COMBUSTION CONTROL CAPABILITY $17,898 $60,000 Not Implemented
LS2023 # 06 Y:2023 06 2023 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $193,754 $552,840 Implemented
LS2023 # 05 Y:2023 05 2023 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,548 $14,800 Implemented
LS2023 # 04 Y:2023 04 2023 REDUCE HEAT GAIN BY WINDOW TINTING $6,749 $10,831 Not Implemented
LS2023 # 03 Y:2023 03 2023 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $189,746 $142,240 Not Implemented
LS2023 # 02 Y:2023 02 2023 INSTALL OCCUPANCY SENSORS $3,665 $1,400 Not Implemented
LS2023 # 01 Y:2023 01 2023 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $56,174 $1,000 Implemented
LT8378 # 05 Y:2023 05 2023 INSTALL OCCUPANCY SENSORS $2,353 $10,050 n/a
LT8378 # 04 Y:2023 04 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $869 $864 n/a
LT8378 # 03 Y:2023 03 2023 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $11,415 $0 n/a
LT8378 # 02 Y:2023 02 2023 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $3,145 $2,591 n/a
LT8378 # 01 Y:2023 01 2023 INSTALL TIMERS AND/OR THERMOSTATS $11,552 $30,450 n/a
LS0123 # 02 Y:2023 02 2023 REPLACE BOILER $17,372 $62,400 Implemented
LS0123 # 01 Y:2023 01 2023 INSTALL OCCUPANCY SENSORS $106 $157 Implemented
LS0123 # 03 Y:2023 03 2023 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $14,146 $54,880 Implemented
LS1922 # 01 Y:2022 01 2022 INSTALL OCCUPANCY SENSORS $2,632 $375 Implemented
LS1922 # 02 Y:2022 02 2022 REDUCE HEAT GAIN BY WINDOW TINTING $1,205 $1,058 Not Implemented
LS1922 # 03 Y:2022 03 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,968 $10,554 Implemented
LS1922 # 04 Y:2022 04 2022 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $11,810 $34,840 Not Implemented
LS1822 # 04 Y:2022 04 2022 INSTALL OCCUPANCY SENSORS $49 $50 Implemented
LS1822 # 01 Y:2022 01 2022 REDUCE HEAT GAIN BY WINDOW TINTING $30,799 $2,056 Implemented
LS1822 # 02 Y:2022 02 2022 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $2,555 $1,292 Not Implemented
LS1822 # 05 Y:2022 05 2022 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $6,150 $23,430 Implemented
LS1822 # 03 Y:2022 03 2022 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $190 $125 Not Implemented
LS1722 # 05 Y:2022 05 2022 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $7,108 $22,697 Implemented