Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

19

matching recommendations
Reset
NAICS 8111 Automotive Repair and Maintenance
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0474 # 02 Y:2011 02 2011 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $2,851 $5,045 Not Implemented
IA0474 # 03 Y:2011 03 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,183 $11,760 Not Implemented
IA0474 # 01 Y:2011 01 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,989 $668 Not Implemented
UA3003 # 08 Y:2010 08 2010 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $1,679 $5,534 Not Implemented
UA3003 # 07 Y:2010 07 2010 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,858 $8,376 Not Implemented
UA3003 # 06 Y:2010 06 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,018 $1,500 Implemented
UA3003 # 05 Y:2010 05 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,872 $640 Not Implemented
UA3003 # 04 Y:2010 04 2010 USE PHOTOCELL CONTROLS $367 $1,000 Implemented
UA3003 # 03 Y:2010 03 2010 INSTALL OCCUPANCY SENSORS $120 $129 Implemented
UA3003 # 02 Y:2010 02 2010 INSTALL OCCUPANCY SENSORS $190 $129 Implemented
UA3003 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,940 $18,577 Not Implemented
MI0065 # 08 Y:2003 08 2003 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,740 $8,820 n/a
MI0065 # 07 Y:2003 07 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $283 $244 n/a
MI0065 # 06 Y:2003 06 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $42 $231 n/a
MI0065 # 05 Y:2003 05 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $370 $85 n/a
MI0065 # 04 Y:2003 04 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $207 $325 n/a
MI0065 # 03 Y:2003 03 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $2,876 $4,556 n/a
MI0065 # 02 Y:2003 02 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $19,897 $1,900 n/a
MI0065 # 01 Y:2003 01 2003 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $12,419 $0 n/a