Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
73
matching recommendationsNAICS | 921 | Executive, Legislative, and Other General Government Support |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK1119 # 03 Y:2024 | 03 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,346 | $11,000 | n/a |
OK1119 # 01 Y:2024 | 01 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,721 | $17,299 | n/a |
OK1119 # 02 Y:2024 | 02 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $24,147 | $120,042 | n/a |
ORC014 # 01 Y:2024 | 01 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,533 | $131,106 | n/a |
ORC014 # 02 Y:2024 | 02 | 2024 | INSTALL OCCUPANCY SENSORS | $4,418 | $448 | n/a |
ORC014 # 03 Y:2024 | 03 | 2024 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $2,420 | $12,690 | n/a |
UL2430 # 01 Y:2024 | 01 | 2024 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $7,574 | $88,000 | n/a |
UL2430 # 02 Y:2024 | 02 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,880 | $16,302 | n/a |
UL2430 # 03 Y:2024 | 03 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $18,630 | $213,973 | n/a |
OK1099 # 04 Y:2023 | 04 | 2023 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $160 | $510 | Implemented |
OK1099 # 03 Y:2023 | 03 | 2023 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $577 | $416 | Not Implemented |
OK1098 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $559 | $2,834 | Implemented |
OK1098 # 02 Y:2023 | 02 | 2023 | REPLACE BOILER | $2,974 | $78,000 | Implemented |
OK1098 # 03 Y:2023 | 03 | 2023 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $75 | $100 | Implemented |
OK1099 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,723 | $5,897 | Not Implemented |
OK1099 # 02 Y:2023 | 02 | 2023 | AIR CONDITION ONLY SPACE NECESSARY | $865 | $0 | Not Implemented |
ORC009 # 05 Y:2023 | 05 | 2023 | INSTALL OCCUPANCY SENSORS | $307 | $200 | Not Implemented |
ORC009 # 01 Y:2023 | 01 | 2023 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $654 | $2,000 | Not Implemented |
ORC009 # 02 Y:2023 | 02 | 2023 | REPLACE BOILER | $1,624 | $10,000 | Not Implemented |
ORC009 # 03 Y:2023 | 03 | 2023 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $178 | $500 | Not Implemented |
ORC009 # 04 Y:2023 | 04 | 2023 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $83 | $400 | Not Implemented |
ORC008 # 02 Y:2023 | 02 | 2023 | INSTALL OCCUPANCY SENSORS | $474 | $100 | Not Implemented |
ORC008 # 06 Y:2023 | 06 | 2023 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,574 | $500 | Not Implemented |
ORC008 # 05 Y:2023 | 05 | 2023 | USE HEAT PUMP FOR SPACE CONDITIONING | $668 | $5,000 | Not Implemented |
ORC008 # 03 Y:2023 | 03 | 2023 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $959 | $1,500 | Not Implemented |