Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
381
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AR0075 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,952 | $6,280 | Implemented |
AR0075 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,148 | $4,243 | Implemented |
AR0075 # 05 Y:1995 | 05 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $9,630 | $758 | Implemented |
AR0075 # 06 Y:1995 | 06 | 1995 | IMPROVE COMBUSTION CONTROL CAPABILITY | $597 | $0 | Not Implemented |
AR0075 # 07 Y:1995 | 07 | 1995 | REPAIR AND ELIMINATE STEAM LEAKS | $2,197 | $800 | Implemented |
AR0075 # 08 Y:1995 | 08 | 1995 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,520 | $2,092 | Implemented |
AR0075 # 09 Y:1995 | 09 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,761 | $50 | Implemented |
AR0075 # 10 Y:1995 | 10 | 1995 | USE COMPRESSOR AIR FILTERS | $17,452 | $50 | Implemented |
AR0075 # 11 Y:1995 | 11 | 1995 | OPTIMIZE PLANT POWER FACTOR | $25,970 | $18,765 | Not Implemented |
AR0075 # 12 Y:1995 | 12 | 1995 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $38,310 | $3,000 | Implemented |
AR0075 # 13 Y:1995 | 13 | 1995 | REMOVE SLUDGE FROM TANKS ON A REGULAR BASIS | $46,125 | $20,000 | Not Implemented |
AR0075 # 14 Y:1995 | 14 | 1995 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $754 | $200 | Implemented |
AR0068 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,425 | $1,844 | Implemented |
AR0068 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17,833 | $39,950 | Implemented |
AR0068 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,361 | $0 | Implemented |
AR0068 # 04 Y:1995 | 04 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $150,834 | $4,000 | Implemented |
AR0068 # 05 Y:1995 | 05 | 1995 | REPAIR AND ELIMINATE STEAM LEAKS | $17,600 | $2,100 | Implemented |
AR0068 # 06 Y:1995 | 06 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,023 | $250 | Implemented |
AR0068 # 07 Y:1995 | 07 | 1995 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $31,656 | $5,000 | Not Implemented |
AR0068 # 08 Y:1995 | 08 | 1995 | MINIMIZE WATER USAGE | $3,519 | $500 | Implemented |
AR0042 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $178 | $142 | Implemented |
AR0042 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,179 | $5,940 | Implemented |
AR0042 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $74 | $100 | Implemented |
AR0042 # 04 Y:1994 | 04 | 1994 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $9,141 | $2,000 | Not Implemented |
AR0042 # 05 Y:1994 | 05 | 1994 | OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS | $16 | $50 | Not Implemented |