IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

575

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0107 # 02 Y:1998 02 1998 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $3,580 $100 Implemented
OD0107 # 03 Y:1998 03 1998 REPAIR OR REPLACE STEAM TRAPS $280 $780 Implemented
MO0227 # 01 Y:1998 01 1998 $3,155 $3,700 Not Implemented
MO0227 # 02 Y:1998 02 1998 $4,071 $9,000 Not Implemented
MO0227 # 03 Y:1998 03 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,132 $6,768 Implemented
MO0227 # 04 Y:1998 04 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $164 $276 Implemented
MO0227 # 05 Y:1998 05 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,109 $139 Implemented
MO0227 # 06 Y:1998 06 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,138 $13,876 Implemented
MO0227 # 07 Y:1998 07 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $469 $0 Implemented
MO0227 # 08 Y:1998 08 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $388,472 $100,000 Not Implemented
MO0227 # 09 Y:1998 09 1998 USE PLASTIC PALLETS INSTEAD OF WOOD $64,000 $31,500 Not Implemented
ME0241 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,669 $38,422 Implemented
ME0241 # 02 Y:1998 02 1998 $12,523 $22,943 Not Implemented
ME0241 # 03 Y:1998 03 1998 INSTALL / REPAIR INSULATION ON STEAM LINES $14,710 $12,260 Implemented
ME0241 # 04 Y:1998 04 1998 $5,602 $7,719 Implemented
ME0241 # 05 Y:1998 05 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,877 $500 Implemented
ME0241 # 06 Y:1998 06 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $444 $804 Implemented
ME0241 # 07 Y:1998 07 1998 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $214 $250 Implemented
ME0241 # 08 Y:1998 08 1998 RECOVER AND REUSE COOLING WATER $47,833 $131,000 Not Implemented
ME0241 # 09 Y:1998 09 1998 MINIMIZE WATER USAGE $2,419 $8,000 Not Implemented
ME0241 # 10 Y:1998 10 1998 USE MINIMUM COOLING WATER TO BEARINGS $2,321 $4,200 Not Implemented
UF0197 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,885 $3,682 Not Implemented
UF0197 # 02 Y:1998 02 1998 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,334 $1,200 Implemented
UF0197 # 03 Y:1998 03 1998 USE COLD WASTE WATER TO COOL CHILLER FEED WATER $15,069 $63,950 Not Implemented
UF0197 # 04 Y:1998 04 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,594 $15,614 Implemented