Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

595

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0372 # 02 Y:1992 02 1992 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $91,322 $0 Not Implemented
KU0372 # 03 Y:1992 03 1992 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $46,997 $208,233 Not Implemented
KU0372 # 04 Y:1992 04 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $35,349 $117,700 Not Implemented
KU0372 # 05 Y:1992 05 1992 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $29,723 $39,435 Not Implemented
KU0372 # 06 Y:1992 06 1992 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $32,127 $90,000 Implemented
KU0372 # 07 Y:1992 07 1992 REPAIR OR REPLACE STEAM TRAPS $29,914 $0 Implemented
KU0372 # 08 Y:1992 08 1992 REPAIR AND ELIMINATE STEAM LEAKS $5,325 $670 Implemented
KU0372 # 09 Y:1992 09 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,789 $10,400 Implemented
KU0372 # 10 Y:1992 10 1992 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $17,785 $70,400 Not Implemented
KU0372 # 11 Y:1992 11 1992 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $6,367 $8,000 Not Implemented
KU0372 # 12 Y:1992 12 1992 INSTALL TIMERS AND/OR THERMOSTATS $4,086 $0 Not Implemented
KU0372 # 13 Y:1992 13 1992 INSULATE BARE EQUIPMENT $3,082 $10,685 Implemented
MO0061 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,377 $18,250 Implemented
MO0061 # 02 Y:1992 02 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,981 $1,170 Implemented
MO0061 # 03 Y:1992 03 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $11,628 $1,240 Implemented
MO0061 # 04 Y:1992 04 1992 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,403 $20 Not Implemented
MO0061 # 05 Y:1992 05 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,455 $14,300 Implemented
MO0061 # 06 Y:1992 06 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,545 $688 Implemented
KU0360 # 01 Y:1991 01 1991 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $11,710 $6,000 Not Implemented
KU0360 # 02 Y:1991 02 1991 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $7,473 $22,500 Not Implemented
KU0360 # 03 Y:1991 03 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,987 $150 Not Implemented
KU0360 # 04 Y:1991 04 1991 INSTALL AUTOMATIC STACK DAMPER $1,794 $2,525 Not Implemented
KU0360 # 05 Y:1991 05 1991 ISOLATE HOT OR COLD EQUIPMENT $1,192 $300 Not Implemented
KU0360 # 06 Y:1991 06 1991 INSTALL SET-BACK TIMERS $770 $1,900 Not Implemented
KU0360 # 07 Y:1991 07 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $377 $310 Not Implemented