Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
595
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0329 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $394 | $700 | Implemented |
KU0329 # 05 Y:1990 | 05 | 1990 | INSTALL SET-BACK TIMERS | $523 | $400 | Implemented |
KU0329 # 06 Y:1990 | 06 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,025 | $0 | Implemented |
KU0329 # 07 Y:1990 | 07 | 1990 | INSULATE BARE EQUIPMENT | $3,165 | $2,804 | Implemented |
KU0314 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $532 | $600 | Implemented |
KU0314 # 02 Y:1990 | 02 | 1990 | INCREASE AMOUNT OF CONDENSATE RETURNED | $20,739 | $22,000 | Implemented |
KU0314 # 03 Y:1990 | 03 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $538 | $0 | Implemented |
KU0314 # 04 Y:1990 | 04 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,014 | $1,587 | Implemented |
KU0314 # 05 Y:1990 | 05 | 1990 | RECOVER AND REUSE COOLING WATER | $5,719 | $2,000 | Implemented |
KU0314 # 06 Y:1990 | 06 | 1990 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $986 | $40 | Not Implemented |
KU0314 # 07 Y:1990 | 07 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $306 | $150 | Implemented |
MO0001 # 01 Y:1990 | 01 | 1990 | MODIFY DYE BECK | $30,784 | $16,000 | Implemented |
MO0001 # 02 Y:1990 | 02 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,122 | $2,500 | Not Implemented |
MO0001 # 03 Y:1990 | 03 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,351 | $900 | Implemented |
MO0001 # 04 Y:1990 | 04 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,805 | $750 | Implemented |
MO0001 # 05 Y:1990 | 05 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $375 | $137 | Implemented |
MO0001 # 06 Y:1990 | 06 | 1990 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $256 | $500 | Not Implemented |
KU0309 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,546 | $12,840 | Implemented |
KU0309 # 02 Y:1990 | 02 | 1990 | LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION | $10,130 | $10,000 | Not Implemented |
KU0309 # 03 Y:1990 | 03 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,042 | $4,000 | Implemented |
KU0309 # 04 Y:1990 | 04 | 1990 | TREAT AND REUSE RINSE WATERS | $5,895 | $4,000 | Implemented |
KU0309 # 05 Y:1990 | 05 | 1990 | INSULATE BARE EQUIPMENT | $386 | $300 | Implemented |
KU0309 # 06 Y:1990 | 06 | 1990 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $126 | $180 | Implemented |
KU0309 # 07 Y:1990 | 07 | 1990 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $22,428 | $20,000 | Not Implemented |
KU0309 # 08 Y:1990 | 08 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,990 | $2,400 | Implemented |