IAC logo
IAC Assessment: KU0309
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: KU0309
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1990
Principal Product HOMOGINIZED MILK & O.J.
NAICS n/a
SIC 2026 - Fluid Milk
Sales $10,000,000-$50,000,000
# of Employees 225
Plant Area (Sq.Ft.) 0
Annual Production 22,000 Thousand Gallons
Production Hrs. Annual 7,488
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $503,333 8,776,378 kWh $0.06
Natural Gas $99,370 37,089 MMBtu $2.68
TOTAL ENERGY COSTS $602,703
RECOMMENDED SAVINGS* $63,543 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $30,985
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$20,546
Cost:
$12,840
$20,546 358,441 - - - - $20,546
358,441
kWh
-
-
MMBtu
-
-
$
02: 2.7263 LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION Savings:
$10,130
Cost:
$10,000
$10,130 176,729 - - - - $10,130
176,729
kWh
-
-
MMBtu
-
-
$
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,042
Cost:
$4,000
$1,042 18,171 - - - - $1,042
18,171
kWh
-
-
MMBtu
-
-
$
04: 3.4113 TREAT AND REUSE RINSE WATERS Savings:
$5,895
Cost:
$4,000
- - - - $5,895 - -
-
kWh
-
-
MMBtu
$5,895
-
$
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$386
Cost:
$300
$386 6,741 - - - - $386
6,741
kWh
-
-
MMBtu
-
-
$
06: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$126
Cost:
$180
- - $126 47 - - -
-
kWh
$126
47
MMBtu
-
-
$
07: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$22,428
Cost:
$20,000
$22,428 391,266 - - - - $22,428
391,266
kWh
-
-
MMBtu
-
-
$
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,990
Cost:
$2,400
$2,990 52,169 - - - - $2,990
52,169
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$63,543
Cost:
$53,720
$57,522 1,003,517 $126 47 $5,895 - $57,522
1,003,517
kWh
$126
47
MMBtu
$5,895
-
$
TOTAL IMPLEMENTED Savings:
$30,985
Cost:
$23,720
$24,964 435,522 $126 47 $5,895 - $24,964
435,522
kWh
$126
47
MMBtu
$5,895
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes