Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
626
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0167 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,356 | $1,280 | Implemented |
UD0167 # 04 Y:1985 | 04 | 1985 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $616 | $0 | Implemented |
UD0167 # 05 Y:1985 | 05 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $10,829 | $29,613 | Not Implemented |
UD0167 # 06 Y:1985 | 06 | 1985 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $3,387 | $7,500 | Not Implemented |
UD0167 # 07 Y:1985 | 07 | 1985 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $3,387 | $7,500 | Not Implemented |
UD0162 # 01 Y:1985 | 01 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,788 | $40 | Implemented |
UD0162 # 02 Y:1985 | 02 | 1985 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $22,693 | $50,000 | Not Implemented |
UD0162 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $312 | $35 | Not Implemented |
UD0162 # 04 Y:1985 | 04 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,806 | $15,000 | Not Implemented |
TS0005 # 01 Y:1985 | 01 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $24,815 | $10,000 | Not Implemented |
TS0005 # 03 Y:1985 | 03 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $8,775 | $18,500 | Not Implemented |
TS0005 # 04 Y:1985 | 04 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $9,545 | $13,580 | Not Implemented |
UD0141 # 01 Y:1984 | 01 | 1984 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,873 | $4,000 | Not Implemented |
UD0141 # 02 Y:1984 | 02 | 1984 | INSULATE BARE EQUIPMENT | $10,040 | $7,500 | Implemented |
UD0141 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,776 | $4,165 | Not Implemented |
UD0141 # 04 Y:1984 | 04 | 1984 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,326 | $400 | Implemented |
UD0141 # 05 Y:1984 | 05 | 1984 | INSULATE BARE EQUIPMENT | $2,799 | $1,000 | Not Implemented |
UD0140 # 01 Y:1984 | 01 | 1984 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $947 | $1,280 | Implemented |
UD0140 # 02 Y:1984 | 02 | 1984 | ISOLATE HOT OR COLD EQUIPMENT | $2,075 | $1,240 | Implemented |
UD0140 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,348 | $708 | Implemented |
UD0140 # 04 Y:1984 | 04 | 1984 | INSULATE BARE EQUIPMENT | $21,331 | $10,185 | Implemented |
UD0140 # 05 Y:1984 | 05 | 1984 | INCREASE AMOUNT OF CONDENSATE RETURNED | $3,213 | $3,000 | Not Implemented |
UD0140 # 06 Y:1984 | 06 | 1984 | REPLACE BOILER | $40,533 | $25,000 | Not Implemented |
UD0140 # 07 Y:1984 | 07 | 1984 | RECOVER AND REUSE COOLING WATER | $1,755 | $0 | Implemented |
UD0140 # 08 Y:1984 | 08 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $983 | $1,500 | Not Implemented |