Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,647
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0492 # 01 Y:2016 | 01 | 2016 | INCREASE AMOUNT OF CONDENSATE RETURNED | $13,265 | $280 | Implemented |
SF0492 # 02 Y:2016 | 02 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $218 | $33 | Implemented |
SF0492 # 03 Y:2016 | 03 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,076 | $5,200 | Implemented |
SF0492 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,543 | $7,437 | Implemented |
SF0492 # 05 Y:2016 | 05 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,830 | $14,614 | Implemented |
SF0492 # 06 Y:2016 | 06 | 2016 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $8,794 | $15,281 | Implemented |
SF0492 # 07 Y:2016 | 07 | 2016 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $6,867 | $11,727 | Implemented |
SF0492 # 08 Y:2016 | 08 | 2016 | INSULATE BARE EQUIPMENT | $7,565 | $13,378 | Implemented |
SF0492 # 09 Y:2016 | 09 | 2016 | INSULATE BARE EQUIPMENT | $165 | $292 | Implemented |
SF0492 # 10 Y:2016 | 10 | 2016 | INSTALL OCCUPANCY SENSORS | $8,681 | $17,643 | Implemented |
SF0492 # 11 Y:2016 | 11 | 2016 | INCREASE AMOUNT OF CONDENSATE RETURNED | $12,365 | $30,659 | Implemented |
SF0492 # 12 Y:2016 | 12 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,145 | $45,338 | Not Implemented |
SF0491 # 01 Y:2016 | 01 | 2016 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $9,190 | $300 | Not Implemented |
SF0491 # 02 Y:2016 | 02 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $25,960 | $7,975 | Not Implemented |
SF0491 # 03 Y:2016 | 03 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,740 | $6,235 | Not Implemented |
SF0491 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,425 | $15,337 | Implemented |
SF0488 # 01 Y:2016 | 01 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $14,980 | $0 | Implemented |
SF0488 # 02 Y:2016 | 02 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,509 | $840 | Implemented |
SF0488 # 03 Y:2016 | 03 | 2016 | INSULATE BARE EQUIPMENT | $6,138 | $882 | Implemented |
SF0488 # 04 Y:2016 | 04 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $464 | $70 | Not Implemented |
SF0488 # 05 Y:2016 | 05 | 2016 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,183 | $1,469 | Implemented |
SF0488 # 06 Y:2016 | 06 | 2016 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $582 | $1,469 | Not Implemented |
SF0488 # 07 Y:2016 | 07 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,217 | $44,943 | Implemented |
SF0488 # 08 Y:2016 | 08 | 2016 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $16,810 | $61,903 | Not Implemented |
SF0489 # 01 Y:2016 | 01 | 2016 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $29,223 | $350 | Implemented |