IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,196

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0362 # 03 Y:2005 03 2005 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $14,498 $0 Not Implemented
UF0362 # 04 Y:2005 04 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $767 $0 Not Implemented
UF0362 # 05 Y:2005 05 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $245 $324 Not Implemented
UF0362 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,793 $16,078 Not Implemented
UF0362 # 07 Y:2005 07 2005 ADD AREA LIGHTING SWITCHES $357 $3,655 Not Implemented
UF0362 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $288 $245 Not Implemented
UF0362 # 09 Y:2005 09 2005 INSULATE BARE EQUIPMENT $1,276 $168 Not Implemented
UF0362 # 10 Y:2005 10 2005 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $8,012 $0 Not Implemented
UF0362 # 11 Y:2005 11 2005 RECYCLE FLUORESCENT LAMPS $355 $3,496 Not Implemented
MI0104 # 01 Y:2005 01 2005 HEAT WATER WITH EXHAUST HEAT $315,984 $128,000 Not Implemented
MI0104 # 02 Y:2005 02 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $23,384 $1,300 Not Implemented
MI0104 # 03 Y:2005 03 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $9,889 $600 Not Implemented
MI0104 # 04 Y:2005 04 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,821 $3,010 Not Implemented
MI0104 # 05 Y:2005 05 2005 UTILIZE A LESS EXPENSIVE COOLING METHOD $8,246 $10,198 Not Implemented
MI0104 # 06 Y:2005 06 2005 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $4,160 $5,060 Not Implemented
MI0103 # 01 Y:2005 01 2005 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $61,700 $195,000 Not Implemented
MI0103 # 02 Y:2005 02 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,798 $906 Not Implemented
MI0103 # 03 Y:2005 03 2005 RECOVER WASTE HEAT FROM EQUIPMENT $2,613 $6,960 Not Implemented
MI0103 # 04 Y:2005 04 2005 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $1,062 $1,536 Not Implemented
MI0103 # 05 Y:2005 05 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,001 $288 Not Implemented
MI0103 # 06 Y:2005 06 2005 INSTALL TIMERS AND/OR THERMOSTATS $556 $486 Not Implemented
MI0101 # 01 Y:2005 01 2005 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $51,010 $72,500 Not Implemented
MI0101 # 02 Y:2005 02 2005 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $12,178 $180 Implemented
MI0101 # 03 Y:2005 03 2005 RECOVER WASTE HEAT FROM EQUIPMENT $7,508 $3,000 Not Implemented
MI0101 # 04 Y:2005 04 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $4,336 $600 Not Implemented