Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
381
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0094 # 10 Y:2012 | 10 | 2012 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $10,016 | $11,318 | Not Implemented |
OK0783 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $112 | $887 | Implemented |
OK0783 # 09 Y:2009 | 09 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,399 | $0 | Implemented |
OK0783 # 08 Y:2009 | 08 | 2009 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $50,901 | $15,708 | Implemented |
OK0783 # 07 Y:2009 | 07 | 2009 | ADJUST BURNERS FOR EFFICIENT OPERATION | $18,978 | $3,810 | Implemented |
OK0783 # 06 Y:2009 | 06 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,392 | $67,320 | Not Implemented |
OK0783 # 05 Y:2009 | 05 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,219 | $15,039 | Not Implemented |
OK0783 # 04 Y:2009 | 04 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,327 | $26,066 | Not Implemented |
OK0783 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,151 | $775 | Implemented |
OK0783 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $29,321 | $280,000 | Not Implemented |
LL0301 # 08 Y:2008 | 08 | 2008 | USE PHOTOCELL CONTROLS | $363 | $150 | Implemented |
LL0301 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,156 | $840 | Implemented |
LL0301 # 06 Y:2008 | 06 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $746 | $1,246 | Not Implemented |
LL0301 # 05 Y:2008 | 05 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,436 | $1,650 | Not Implemented |
LL0301 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,117 | $2,720 | Implemented |
LL0301 # 03 Y:2008 | 03 | 2008 | INSULATE BARE EQUIPMENT | $11,367 | $11,696 | Implemented |
LL0301 # 02 Y:2008 | 02 | 2008 | INSULATE BARE EQUIPMENT | $86,230 | $9,006 | Implemented |
LL0301 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $230,177 | $13,140 | Implemented |
LL0284 # 08 Y:2007 | 08 | 2007 | INSULATE BARE EQUIPMENT | $155 | $102 | Not Implemented |
LL0284 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,030 | $451 | Not Implemented |
LL0284 # 06 Y:2007 | 06 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,700 | $2,074 | Not Implemented |
LL0284 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,314 | $2,100 | Not Implemented |
LL0284 # 04 Y:2007 | 04 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,900 | $1,500 | Not Implemented |
LL0284 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,045 | $12,575 | Not Implemented |
LL0284 # 02 Y:2007 | 02 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $33,682 | $1,600 | Not Implemented |