Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

300

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0499 # 04 Y:2021 04 2021 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,271 $5,600 Implemented
LE0474 # 04 Y:2019 04 2019 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $17,687 $22,000 Not Implemented
LE0474 # 03 Y:2019 03 2019 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $28,595 $35,000 Not Implemented
LE0474 # 02 Y:2019 02 2019 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $30,754 $20,000 Not Implemented
LE0474 # 01 Y:2019 01 2019 INSTALL TIMERS AND/OR THERMOSTATS $6,222 $0 Not Implemented
LE0474 # 05 Y:2019 05 2019 PREHEAT COMBUSTION AIR WITH WASTE HEAT $73,547 $220,000 Not Implemented
LE0474 # 06 Y:2019 06 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,789 $6,400 Not Implemented
LE0474 # 07 Y:2019 07 2019 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $150,418 $721,000 Not Implemented
LE0474 # 08 Y:2019 08 2019 USE SOLAR HEAT TO MAKE ELECTRICTY $41,537 $280,000 Not Implemented
DL0172 # 07 Y:2017 07 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,657 $32,101 Not Implemented
DL0172 # 06 Y:2017 06 2017 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $31,647 $428,406 Not Implemented
DL0172 # 05 Y:2017 05 2017 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $1,205 $0 Not Implemented
DL0172 # 04 Y:2017 04 2017 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $2,018 $0 Not Implemented
DL0172 # 03 Y:2017 03 2017 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $3,765 $382 Not Implemented
DL0172 # 02 Y:2017 02 2017 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $3,948 $192 Not Implemented
DL0172 # 01 Y:2017 01 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,137 $8,000 Implemented
DL0172 # 08 Y:2017 08 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,972 $48,444 Not Implemented
DL0147 # 01 Y:2015 01 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,550 $9,700 Not Implemented
DL0147 # 02 Y:2015 02 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $16,890 $32,055 Not Implemented
DL0147 # 03 Y:2015 03 2015 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $27,680 $73,960 Implemented
DL0147 # 04 Y:2015 04 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,470 $21,000 Implemented
LE0394 # 10 Y:2015 10 2015 INSTALL / REPAIR INSULATION ON STEAM LINES $207 $550 Not Implemented
LE0394 # 08 Y:2015 08 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,987 $4,340 Not Implemented
LE0394 # 09 Y:2015 09 2015 PREHEAT COMBUSTION AIR WITH WASTE HEAT $8,298 $20,000 Not Implemented
LE0394 # 06 Y:2015 06 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,528 $5,688 Not Implemented